A low noise highly integrated bolometer array for absolute measurement of VUV and soft x radiation

Abstract: A new low noise miniaturized multichannel bolometer module for absolute measurements in the VUV and soft x spectral ranges is described. Highly integrated four-channel modules (2×3.3×1.5 cm3) each comprising four independent ac-excited (50 kHz) metal resistor bolometer bridges were successfully tested on a large tokamak (Tore Supra in Cadarache) and on an electron synchrotron (BESSY in Berlin). The bolometer system features a linear response to the absorbed radiation power, a low detection limit (≤1.0×10−6 W c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
80
0
1

Year Published

1996
1996
2011
2011

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 146 publications
(85 citation statements)
references
References 6 publications
0
80
0
1
Order By: Relevance
“…The digitized signals of up to 128 channels are transferred serially to a single PXI 7813R FPGA card with 4 x 40 DIO connectors from four modules. The raw signal from four bolometer channels during a discharge is shown in Fig 1. In comparison with the AC system previously described [18], the offset compensation is greatly simplified. The AD7730 has several features including the ability to correct the DC bridge offset due to a mismatch of the meander resistances, ratiometric measurement of the bridge voltage and square wave excitation which avoids complications arising from cable capacitance when using AC excitation.…”
Section: Bolometermentioning
confidence: 99%
See 1 more Smart Citation
“…The digitized signals of up to 128 channels are transferred serially to a single PXI 7813R FPGA card with 4 x 40 DIO connectors from four modules. The raw signal from four bolometer channels during a discharge is shown in Fig 1. In comparison with the AC system previously described [18], the offset compensation is greatly simplified. The AD7730 has several features including the ability to correct the DC bridge offset due to a mismatch of the meander resistances, ratiometric measurement of the bridge voltage and square wave excitation which avoids complications arising from cable capacitance when using AC excitation.…”
Section: Bolometermentioning
confidence: 99%
“…The temperature increase of the bolometer foil, resulting from heating of the four micron thick platinum absorber by radiated power from the plasma, is measured as a voltage difference on a Wheatstone bridge [18] using the AD7730 (Analog Devices) bridge amplifier. A 5 V square wave at 2 kHz is applied to the Wheatstone bridge arrangement of a bolometer foil [19].…”
Section: Bolometermentioning
confidence: 99%
“…A bolometer measures the plasma radiation over a wide spectral range (from soft-X to the infrared) by monitoring the temperature rise induced by deposition of photon energy in the absorber layer of the bolometer. The reference detector type chosen for ITER is the metal resistor bolometer [1,2]. In order to derive the spatially resolved radiation emission profile from the line integrated measurements tomographic reconstruction methods are applied to the measurements of many lines-of-sight (e.g.…”
Section: Introductionmentioning
confidence: 99%
“…The bolometer system planned for W7-X consists mainly of metal (Au) resistive detector arrays [1] already widely used for other devices [2][3][4]. In addition to measuring the total radiated power, the bolometer system is capable of performing tomographic reconstruction of spatial radiation distribution.…”
Section: Introductionmentioning
confidence: 99%