2013
DOI: 10.1039/c2em30568b
|View full text |Cite
|
Sign up to set email alerts
|

A low-cost particle counter as a realtime fine-particle mass monitor

Abstract: Exposure to particles with aerodynamic diameters less than 2.5 μm is estimated to cause significant morbidity and mortality worldwide leading many countries to develop ambient air pollution standards and guidelines. At local scales, community and environmental justice groups are also concerned about PM 2.5 concentrations that may be elevated above regional concentrations typically measured by centrally located monitors and standards as well. In an attempt to develop a low cost, easy to use monitor we evaluated… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

4
82
0
1

Year Published

2015
2015
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(92 citation statements)
references
References 17 publications
4
82
0
1
Order By: Relevance
“…The Dylos has been used and evaluated in other studies, both indoors and outdoors, e.g. by Semple et al (2012Semple et al ( , 2013, in the context of exposure to SHS, and by Northcross et al (2013) and Holstius et al (2014) who compared the performance of the Dylos against other commercially-available particle monitors (both for chamber and ambient environments).…”
Section: Portable Monitoring Solutionmentioning
confidence: 99%
“…The Dylos has been used and evaluated in other studies, both indoors and outdoors, e.g. by Semple et al (2012Semple et al ( , 2013, in the context of exposure to SHS, and by Northcross et al (2013) and Holstius et al (2014) who compared the performance of the Dylos against other commercially-available particle monitors (both for chamber and ambient environments).…”
Section: Portable Monitoring Solutionmentioning
confidence: 99%
“…Fully integrated (i.e., miniaturized electronic circuitries, microfilter, impactor, PLL, and LCD), compact, handheld, lowcost (<200 €, at a total quantity of 100), easy to use, batteryoperated Dylos Corp., USA [23] Scattering of laser light $400 g, < 1 lg/m 3 , realtime Particle diameter > 0.5 lm, price < $300…”
Section: Real-time Engineered Nanoparticle Exposure Assessmentmentioning
confidence: 99%
“…Moreover, the particles detected by the devices from McGill University, DU, and BSAC were microparticles. Besides MEMS-based NP mass sensors, portable non-MEMS-based particle monitoring instruments are also available with different sensing mechanisms (i.e., Dylos Corp., USA [23] with scattering of laser light and Naneos Particle Solution GmbH, Switzerland [8] with charging of particles and charge measurement using electrometer). Electrophoretic precipitator and self-exciting and self-sensing in-plane silicon cantilever resonator (CANTOR-2) 375 g, 5 lg/m 3 , 6 s…”
Section: Real-time Engineered Nanoparticle Exposure Assessmentmentioning
confidence: 99%
See 1 more Smart Citation
“…Correspondingly, production of a second commercial DC (Nanotracer, Philips, Netherlands) was stopped in 2012 [6]. A low-cost optical particle counter (OPC) based on the commercial Dylos Air Quality Monitor, which is available at < $300, is based on optical scattering (650 nm), i.e., NPs with diameters of less than 300 nm cannot be detected [7]. Furthermore, calculation of mass concentrations c m from measured NP number concentrations requires knowledge on their shape and density.…”
Section: Introductionmentioning
confidence: 99%