2023
DOI: 10.1101/2023.10.17.562754
| |Summarize |Cite
Preprint
|
Sign up to set email alerts

A Histomorphometric and Computational Investigation of the Stabilizing Role of Pectinate Ligaments in the Aqueous Outflow Pathway

Abstract: Murine models are commonly used to study glaucoma, the leading cause of irreversible blindness in humans. Blindness in glaucoma is associated with intraocular pressure (IOP), which is generated and regulated by the tissues of the aqueous outflow pathway. One of the main components of the aqueous humor pathway are the pectinate ligaments (PLs) that connect iris and trabecular meshwork at the anterior chamber angle. However, their role in helping maintain the biomechanical stability of murine aqueous outflow pat… Show more

View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
0

Citation Types

0
4
0
0

Year Published

Range
2023
2023
2025
2025

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

Cited by 3 publications

(4 citation statements)

References 53 publications

0
4
0
0
Order By: Relevance
How the paper below cites the one you are viewing
“…Part of the observed minor increase in facility (Figure 5B and Supplementary Figures 1C and 3A) can be attributed to age-related morphological changes such as increased globe size, and thus a corresponding increase in TM cross-sectional area with age [64]. After adjusting for TM area, the correlation coefficient became statistically indifferent to zero, implying no change in conductivity of the TM/SC.…”
Section: Discussion
mentioning
confidence: 99%
“…This area is equal to the circumference of the toroidal SC (approximately equal to limbal circumference) multiplied by SC anterior-posterior length, both of which have been observed to increase with age, but only modestly [64]. Normalization by area would give a conductivity (facility/area) with hard-to-interpret units [nl/min/mmHg/mm 2 ] and involve an estimate of SC anterior-posterior length, which showed significant inter-animal variability [64]. Instead, we used our correlation between age and ocular diameter to adjust the measured reference facility to the value that would be expected for an eye of the average diameter of the eyes used in this study ().…”
Section: Methods
mentioning
confidence: 99%
“…In brief, increasing IOP deforms the TM and partially collapses SC lumen; we tracked luminal collapse as the main OCT imaging outcome measure, which we then fit with our finite element model. The full modeling methodology is beyond the scope of this paper and is described elsewhere [64]. In brief, we used the FEBio finite element software [80] to simulate age-specific models, evaluating TM/SC deformations vs. IOP and adjusted TM stiffness so that finite element predictions of SC lumen partial collapse matched those observed experimentally by OCT.…”
Section: Methods
mentioning
confidence: 99%
“…Facility is expected to be dependent on the cross-sectional area of the inner wall of SC through which the fluid filters. This area is equal to the circumference of the toroidal SC (approximately equal to limbal circumference) multiplied by SC anterior-posterior length, both of which have been observed to increase with age, but only modestly [64]. Normalization by area would give a conductivity (facility/area) with hard-to-interpret units [nl/min/mmHg/mm 2 ] and involve an estimate of SC anterior-posterior length, which showed significant inter-animal variability [64].…”
Section: Methods
mentioning
confidence: 99%
See 3 more Smart Citations

Aging and intraocular pressure homeostasis in mice

Li,
van Batenburg-Sherwood,
et al. 2023
Preprint
Self Cite