2022
DOI: 10.1016/j.snb.2022.132483
|View full text |Cite
|
Sign up to set email alerts
|

A highly flexible, physically stable, and selective hydrogel-based hydrogen peroxide sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(13 citation statements)
references
References 74 publications
0
13
0
Order By: Relevance
“…tears, saliva, sweat as well as intestinal secretions are more Manufacturing process of PEDOT:PSS/HPU/HRP film and its structure. 137,141 applicable practically. 132 This provides more appropriate information regarding the health status and function of the human body.…”
Section: Mxenes Based Biosensorsmentioning
confidence: 99%
“…tears, saliva, sweat as well as intestinal secretions are more Manufacturing process of PEDOT:PSS/HPU/HRP film and its structure. 137,141 applicable practically. 132 This provides more appropriate information regarding the health status and function of the human body.…”
Section: Mxenes Based Biosensorsmentioning
confidence: 99%
“…The amount of peroxides, defined as mill equivalents (meq), reflects the active oxygen per kilogram of oil. Edible oils produce a sour taste and may even cause food poisoning when the PV exceeds a critical value (Gotoh and Wada, 2006). Therefore, from the perspective of food quality and human health, the PV of edible oils needs to be determined.…”
Section: The Importance Of Measuring Peroxide Value In Oilmentioning
confidence: 99%
“…Benefiting from the coredox of PEDOT: PSS and HRP, this sensor showed high stability, fast response (<6 s) and high selectivity, as well as a linear range from 100 μM to 101.6 mM by amperometric technique. The PEDOT: PSS hydrogel-based sensor was stable in liquid media without washing after a 2-month storage period in aqueous media (Giaretta et al , 2022).…”
Section: H2o2 Sensors Based On Hydrogelmentioning
confidence: 99%
“…In this design, PEDOT:PSS acts as the transducer, HPU serves as the hydrogel matrix, and HRP functions as the specific redox enzyme for H 2 O 2 . These sensors demonstrate remarkable stability, with response times of less than 6 s, and offer a detection range spanning from 100 µM to 101.6 mM [ 317 ]. The flexibility and mechanical stability of this hydrogel-based electrochemical sensor make it well-suited for wearable applications.…”
Section: Applications Of Hwebsmentioning
confidence: 99%