Abstract: With the nonlinear and unbalanced loads and high penetration of distributed generations connected into the power distribution network, some deteriorative influences such as poor power quality and stability issues have been caused. Static synchronous compensator (STATCOM) and another custom power device, electric spring (ES) are competent for solving these problems. This paper provides a general comparative analysis of STATCOM and ES on fundamental principles, control strategies and power quality improvement fu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 17 publications
(24 reference statements)
0
4
0
Order By: Relevance
“…2. FACTS devices such as STATCOM as well as DVR provide a compensation of single point at the level of transmission and must therefore be mounted with far higher ratings, where ES works at several locations such as an inherent part of the partial load, which is also at the level of distribution and therefore less costly due to lower ratings [34].…”
Section: Comparison Of Electric Spring (Es) With Factsmentioning
confidence: 99%
See 1 more Smart Citation
“…2. FACTS devices such as STATCOM as well as DVR provide a compensation of single point at the level of transmission and must therefore be mounted with far higher ratings, where ES works at several locations such as an inherent part of the partial load, which is also at the level of distribution and therefore less costly due to lower ratings [34].…”
Section: Comparison Of Electric Spring (Es) With Factsmentioning
confidence: 99%
“…3. Electric Spring is nothing but source of voltage controlled by current, while FACTS is a source of voltage controlled equipment [35].…”
Section: Comparison Of Electric Spring (Es) With Factsmentioning
confidence: 99%
“…Refrigeration, lighting, and heating loads are generally classified as noncritical loads. Previous reported uses of ES include its usage for voltage regulation, harmonic mitigation, and demand side management [18][19][20][21][22][23][24]. In addition, the ES has also been used to reduce energy storage requirement [25] and threephase load imbalance [26,27].…”
Section: System Fundamentalsmentioning
confidence: 99%
“…Unlike the traditional circuit compensation device, the ES operates in a distributed manner on the load side, making the power consumption more reliable on the load side [4]. Compared with the static var compensator (SVC), the ES boasts small capacity and high reliability [5]. Different from the traditional measures to alleviate RES supply fluctuations (e.g.…”
Section: Introductionmentioning
confidence: 99%