1999
DOI: 10.1016/s0022-3115(98)00569-8
|View full text |Cite
|
Sign up to set email alerts
|

A fast scanning Langmuir probe system for ASDEX-Upgrade divertor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
32
1

Year Published

2006
2006
2013
2013

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(35 citation statements)
references
References 10 publications
2
32
1
Order By: Relevance
“…The neutrals then travel upstream in a 2D way by leaving the zone sidewards and getting through multiple reflections at the side walls and the plasma into hotter upstream regions where they are ionised (5-7 eV) [62]. In this ionisation front zone one drives quite large Mach flows even up to or above Mach 1 (as measured with a fast movable Langmuir divertor probe [156]) due to the large neutral sources there (Fig. 128).…”
Section: Detachment Propertiesmentioning
confidence: 99%
“…The neutrals then travel upstream in a 2D way by leaving the zone sidewards and getting through multiple reflections at the side walls and the plasma into hotter upstream regions where they are ionised (5-7 eV) [62]. In this ionisation front zone one drives quite large Mach flows even up to or above Mach 1 (as measured with a fast movable Langmuir divertor probe [156]) due to the large neutral sources there (Fig. 128).…”
Section: Detachment Propertiesmentioning
confidence: 99%
“…Impurity transport is related to material migration, tritium co-deposition, and core contamination -issues that are crucial for ITER and commercial fusion power. The radial profiles of the SOL flow has been measured in ASDEX Upgrade (AUG) close to the x-point for both divertor legs using a reciprocating Langmuir probe [3] and spectroscopy [4], and in the low field side (LFS) midplane using a Langmuir probe [5]. Also, charge exchange recombination spectroscopy (CXRS) core rotation measurements exists for both the HFS [6] and LFS [7].…”
Section: Introductionmentioning
confidence: 99%
“…Electrical probe diagnostics (EPDs) have been well known as a useful tool for the diagnosis of the characteristics of edge plasmas in tokamak machines [1][2][3]. It is required to measure plasma parameters in the edge region such as divertor and scrape off layer (SOL) in order to understand the phenomena in the edge plasma and to minimize the effect of the plasma wall interaction on the global performance of plasma because influx of impurity from wall due to plasma wall interaction may cause to contaminate the central plasma.…”
Section: Introductionmentioning
confidence: 99%