2018
DOI: 10.1002/elan.201800658
|View full text |Cite
|
Sign up to set email alerts
|

A Facile Strategy for Construction of Sensor for Detection of Ondansetron and Investigation of its Redox Behavior and Thermodynamic Parameters

Abstract: A sodium dodecylsulfate‐doped polypyrrole (SDS‐PPy) film was elaborated on glassy carbon electrode (GCE) by an electrodeposition method in phosphate buffer solution (pH 2.0) containing pyrrole (Py) and sodium dodecyl sulfate (SDS). SDS‐PPy/GCE was used for the construction of sensor, which showed excellent electrochemical response for the detection of ondansetron (OND) compared to conventional PPy. The application of the square wave (SW), with the adsorptive accumulation, indicates a maximum response at 1.33 V… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 32 publications
0
5
0
Order By: Relevance
“…Electrically conductive polymers are a class of materials that can be fabricated to generate either transient or static electrical charges because of their physico-chemical properties [ 4 ]. Among those polymers, PPy is the most extensively used as a conducting polymer in electrochemical sensing applications because it is a heterocyclic conducting polymer, with good environmental stability, high electronic conductivity, and biocompatibility compared to other CPs [ 5 , 6 , 7 , 8 ].…”
Section: Introductionmentioning
confidence: 99%
“…Electrically conductive polymers are a class of materials that can be fabricated to generate either transient or static electrical charges because of their physico-chemical properties [ 4 ]. Among those polymers, PPy is the most extensively used as a conducting polymer in electrochemical sensing applications because it is a heterocyclic conducting polymer, with good environmental stability, high electronic conductivity, and biocompatibility compared to other CPs [ 5 , 6 , 7 , 8 ].…”
Section: Introductionmentioning
confidence: 99%
“…reported a glass carbon electrode modified by sodium dodecyl sulfate‐polypyrrole. The electrode showed an excellent electrochemical response to ondansetron [8] . Finally, Abbas et al .…”
Section: Introductionmentioning
confidence: 92%
“…The result can be justified by the removal of drug positive charge and transition into the molecular state where the solubility in the aqueous solution drastically diminished. [17] Thus, a pH value 4.5 [17] (OND + molybdophosphoric acid) + DBPh 59.610 7.30 × 10 À 5 -1.00 × 10 À 2 -3 - [9] (tetrakis as an ion exchanger, and calix-[4]-arene as an ionophore) + Te recipe included NPOE as a plasticizer, 59.700 2.68 × 10 À 5 -4.07 × 10 À 4 5.32 -100.01-98.26 [6a] Voltammetric Sensor carbon paste electrode modified electrode with Polyvinyl Pyrrolidone and multi-walled carbon nanotube -2.00 × 10 À 9 -2.00 × 10 À 7 430 × 10 À 6 -- [7] A sodium dodecylsulfate-doped polypyrrole film elaborated on a glassy carbon electrode -1.00 × 10 À 6 -8.00 × 10 À 5 0.30 0.09 - [8] Figure 5. Effect of pH on the potential response of (OND-RA).PVC.SE.…”
Section: Effect Of Phmentioning
confidence: 99%
See 1 more Smart Citation
“…2,3 For anti-anxiety, the normal dosage is 8-32 mg per day, and for anxiety disorder, the initial results from clinical recommendations suggested lower levels of 2-4 mg per day. 3 Over time, methods have been developed for the determination of ondansetron by liquid chromatography (LC), 4,5 highperformance liquid chromatography (HPLC), 6,7 ion-pair chromatography, 8 liquid chromatography mass spectrometry (LC-MS), 9,10 capillary zone electrophoresis, 11,12 ow injection atomic absorption spectroscopy, and ultraviolet (UV) spectrophotometry. [13][14][15] Ninama et al improved and validated a mass spectrometry method for concentrations of 1.00-100.00 ng mL À1 with a lower limit of quantitation (LLOQ) at approximately 1.00 ng mL À1 , and shorter stability time for analysis of ondansetron solutions at approximately 7 h 10 min.…”
Section: Introductionmentioning
confidence: 99%