2000
DOI: 10.1016/s0140-7007(99)00046-8
|View full text |Cite
|
Sign up to set email alerts
|

A design method of thermoelectric cooler

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

4
68
1
3

Year Published

2008
2008
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 201 publications
(98 citation statements)
references
References 4 publications
4
68
1
3
Order By: Relevance
“…The heat released from the actuator is absorbed by the cold side of a thermoelectric cooler, and pumped to the hot side. The pumped heat with the input power to the cooler is then extricated to the ambient through a heat sink (Huang & Duang, 2000). , cooling load, which is conducted from the cold side to the hot side, should be greater than the heat generated by the coil for the proper cooling.…”
Section: Design and Analysis Of Tecmentioning
confidence: 99%
“…The heat released from the actuator is absorbed by the cold side of a thermoelectric cooler, and pumped to the hot side. The pumped heat with the input power to the cooler is then extricated to the ambient through a heat sink (Huang & Duang, 2000). , cooling load, which is conducted from the cold side to the hot side, should be greater than the heat generated by the coil for the proper cooling.…”
Section: Design and Analysis Of Tecmentioning
confidence: 99%
“…The next step in the proposed procedure is aimed to obtain the value of parameter , which is the parameter directly related to the thermoelectric effect. Knowing the value of it is possible to apply equation 2 also for T=0, hence The method to estimate these parameters based on Imax, Vmax, Qmax and Tmax [6] differ from these values 18,5% in the worst case. The main reason for a better accuracy of the method presented in this paper is the use of several data point read from the datasheet graphs instead of using just the values corresponding to the most extreme condition.…”
Section: Estimating Parameters From Performance Curvesmentioning
confidence: 99%
“…From the small number of publications related to this topic, the most significant are the experimental procedure described by Huang [6] and the mathematical methods described by Luo [5].…”
Section: Introductionmentioning
confidence: 99%
“…The thermoelectric module has several advantages such as accuracy, no noise, a small size, and it is eco-friendly. For these reasons, the thermoelectric module has been widely used in the military industry, the medical field, and in many commercial products [1][2][3][4]. In this research, the theoretical design and analysis of a thermoelectric cooler is presented.…”
Section: Introductionmentioning
confidence: 99%