2015
DOI: 10.1016/j.compmedimag.2015.09.004
|View full text |Cite
|
Sign up to set email alerts
|

A bifurcation identifier for IV-OCT using orthogonal least squares and supervised machine learning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
30
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 27 publications
(33 citation statements)
references
References 28 publications
2
30
0
Order By: Relevance
“…Briefly, the lumen contour from each IVOCT frame is obtained after two processes based on Macedo et al (2015b): i) preprocessing and ii) lumen contour detection, as shown in Figure 1. The pre-processing stage includes speckle noise removal, catheter and the guide-wire; moreover, a binarization is performed to highlight the intimal layer.…”
Section: Methods To Segment the Vessel Lumenmentioning
confidence: 99%
“…Briefly, the lumen contour from each IVOCT frame is obtained after two processes based on Macedo et al (2015b): i) preprocessing and ii) lumen contour detection, as shown in Figure 1. The pre-processing stage includes speckle noise removal, catheter and the guide-wire; moreover, a binarization is performed to highlight the intimal layer.…”
Section: Methods To Segment the Vessel Lumenmentioning
confidence: 99%
“…10 In such scenarios, lumen segmentation methods cannot guarantee an accurate lumen contour for the affected regions. Corrupted lumen contours can affect the lumen quantification methods such as geometrical analysis 3,4 of the contour to identify bifurcation points of the side branches. To overcome this, a scheme is presented wherein low-intensity lumen regions of the side branches were identified and subsequently the erroneous contour sections were masked out.…”
Section: Compensation Of Lumen Contour Atmentioning
confidence: 99%
“…1 Automated assessment can reduce this error and produce more consistent image interpretation. Various techniques have been reported for lumen segmentation, [1][2][3][4][5][6][7][8] stent strut detection, 7 and plaque characterization. 1,9 These approaches are either semi or fully automated.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…For this study, we used the intensity profile for each column of a 2D IOCT in polar coordinates as input signal for the CWT. Note that this polar image is centered in the lumen centroid, the lumen border was extracted with a method described in [8]. Each column of this image (A-line) is a intensity profile as depicted in Figure 2 b.…”
Section: Multiresolution Analysismentioning
confidence: 99%