Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2008
2008
2019
2019

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 38 publications
(13 citation statements)
references
References 9 publications
0
13
0
Order By: Relevance
“…This should be attributed to the exible porous framework, the higher affinity of the chalcogenide for the so Cs + and Sr 2+ ions and the excellent ion-exchange abilities of small organic amines. The equilibrium time is longer time than that at 65 C (5 minutes for Cs + and Sr 2+ ), but is still comparable to those of other ion-exchangers including the commercial UOP IONSIV IE-911 whose equilibrium time is more than 4 h. [62][63][64][65][66][67][68][69][70][71][72] The Cs + equilibrium curve is graphed in Fig. 33 The Cs + ion replaced the [Me 2 NH 2 ] + or [Me 3 NH] + cations immediately at the beginning and progressively a small fraction of [Me 2 NH 2 ] + or [Me 3 NH] + re-entered the interlayer spaces releasing some Cs + ion back to the solution.…”
Section: Kinetic and Isotherm Studies Of Ion Exchangementioning
confidence: 85%
“…This should be attributed to the exible porous framework, the higher affinity of the chalcogenide for the so Cs + and Sr 2+ ions and the excellent ion-exchange abilities of small organic amines. The equilibrium time is longer time than that at 65 C (5 minutes for Cs + and Sr 2+ ), but is still comparable to those of other ion-exchangers including the commercial UOP IONSIV IE-911 whose equilibrium time is more than 4 h. [62][63][64][65][66][67][68][69][70][71][72] The Cs + equilibrium curve is graphed in Fig. 33 The Cs + ion replaced the [Me 2 NH 2 ] + or [Me 3 NH] + cations immediately at the beginning and progressively a small fraction of [Me 2 NH 2 ] + or [Me 3 NH] + re-entered the interlayer spaces releasing some Cs + ion back to the solution.…”
Section: Kinetic and Isotherm Studies Of Ion Exchangementioning
confidence: 85%
“…The utilization of radioactive isotopes to infer the uptake of a given element is already well known in the literature namely for Hg sorbents, nonetheless its usage does not make the most of radioactive trackers capabilities [17][18][19][20][21] . As a matter of fact, aspects such as the sensitivity, traceability and element specificity are not exploited in reported uptake studies using radioisotopes, where a more qualitative approach is favoured, underusing the radioisotopes characteristics [17][18][19][20][21] . This manuscript works as a proof of concept for the usage of radioactive trackers as a means of a very sensitive quantitative analysis of toxic metals uptake studies (Hg in particular).…”
Section: Advantages Of Radio-trackers For Hg Uptake Characterizationmentioning
confidence: 99%
“…This material can be used in many sectors thanks to its particular peculiarities. It has properties of ion exchange [27,28,29], adsorption [30,31,32,33,34,35], and also photocatalytic properties [36,37,38,39,40,41]. The coexistence of these properties makes these materials particularly and potentially interesting thanks to the possibility of creating a perfect synergy between them, which can be applied advantageously for the removal and degradation of common environmental pollutants such as polycyclic aromatic hydrocarbons, cycloalkanes, benzene, toluene, ethylbenzene, etc.…”
Section: Introductionmentioning
confidence: 99%