2021 IEEE 34th International Conference on Micro Electro Mechanical Systems (MEMS) 2021
DOI: 10.1109/mems51782.2021.9375359
|View full text |Cite
|
Sign up to set email alerts
|

9.5 % Scandium Doped ALN PMUT Compatible with Pre-Processed CMOS Substrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 9 publications
0
4
0
Order By: Relevance
“…To validate the proposed MFPW algorithm for ultrasound distance measurements in liquid, an 80 µm squared piezoelectric micromachined ultrasonic transducer (PMUT), fabricated with the MEMS-on-CMOS process from Silterra was used [ 16 , 17 ]. In this case the PMUT is composed of 1.2 μm AlScN (Aluminium Nitride doped with 9.5 % Scandium) sandwiched between aluminum electrodes and covered by 1.5 μm Silicon Nitride as elastic layer [ 18 ]. The PMUT was wire bonded to a printed circuit board (PCB) and immersed in Fluorinert (FC-70).…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…To validate the proposed MFPW algorithm for ultrasound distance measurements in liquid, an 80 µm squared piezoelectric micromachined ultrasonic transducer (PMUT), fabricated with the MEMS-on-CMOS process from Silterra was used [ 16 , 17 ]. In this case the PMUT is composed of 1.2 μm AlScN (Aluminium Nitride doped with 9.5 % Scandium) sandwiched between aluminum electrodes and covered by 1.5 μm Silicon Nitride as elastic layer [ 18 ]. The PMUT was wire bonded to a printed circuit board (PCB) and immersed in Fluorinert (FC-70).…”
Section: Resultsmentioning
confidence: 99%
“…Considering that the acoustic pressure distribution in far-field of the used PMUT presents an exponential dependence with the distance (2.66/z Pa pp ) [ 18 ], being z the axial distance, the rms voltage at the output of Hydrophone’s preamplifier (V a,rms ) is given by: where M is the reception sensitivity at the output of hydrophone’s preamplifier (11.22 μV/Pa) [ 21 ]. In our case, the measured amplitudes are inside a range from 4.2 (corresponding to the reference point located at 2.5 mm) to 3 mV rms (3.5 mm).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…This is due to the film's significantly lower dielectric permittivity, despite its smaller piezoelectric coefficients, as compared to other piezoelectrics like PZT [11]. The use of Scandium doping in the piezoelectric layer of PMUTs has also been proven to offer improved performance, in terms of sensitivity, as compared to identical devices based on pure AlN [12], [13].…”
Section: Introductionmentioning
confidence: 99%