2000
DOI: 10.1016/s0301-5629(00)00278-7
|View full text |Cite
|
Sign up to set email alerts
|

40 MHz Doppler characterization of umbilical and dorsal aortic blood flow in the early mouse embryo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
114
2

Year Published

2005
2005
2024
2024

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 102 publications
(126 citation statements)
references
References 22 publications
10
114
2
Order By: Relevance
“…Due to differences in experimental procedure and equipment design, it is difficult to make comparisons with ultrasound studies carried out with ultra-high frequency biomicroscopes. In some of the biomicroscope studies, a semi-invasive procedure involving exteriorizing the uterine horns was used, which can affect lhemodynamic function (Phoon et al, 2000(Phoon et al, , 2004. The slower frame rates of biomicroscopes (8-30 Hz as compared to 60 Hz in clinical ultrasound systems) also made it difficult to obtain images of the heart at true end-diastole and end-systole.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Due to differences in experimental procedure and equipment design, it is difficult to make comparisons with ultrasound studies carried out with ultra-high frequency biomicroscopes. In some of the biomicroscope studies, a semi-invasive procedure involving exteriorizing the uterine horns was used, which can affect lhemodynamic function (Phoon et al, 2000(Phoon et al, , 2004. The slower frame rates of biomicroscopes (8-30 Hz as compared to 60 Hz in clinical ultrasound systems) also made it difficult to obtain images of the heart at true end-diastole and end-systole.…”
Section: Discussionmentioning
confidence: 99%
“…Mouse fetal echocardiography has been carried out using standard clinical ultrasound systems (Gui et al 1996;Spurney et al 2004), as well as ultra-high frequency ultrasound systems, also referred to as ultrasound biomicroscopes (Srinivasan et al 1998;Phoon et al 2000Phoon et al , 2004Foster et al 2002;Zhou et al 2002Zhou et al , 2003. Ultra high frequency ultrasound systems equipped with 30-40 MHz transducers have greatly improved 2D spatial resolution that allow even very early mouse embryos (from embryonic day 5.5) to be imaged (Srinivasan et al 1998;Phoon et al 2000;Foster et al 2002).…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Since the initial study of mouse embryos in utero (Turnbull et al, 1995a), ultrasonography has been used for imaging and staging early postimplantation embryos in utero (Turnbull, 1999;Chang et al, 2003), and both transcutaneous and transuterine UBM has become a standard method for assessing normal and defective cardiovascular development in mice (Srinivasan et al, 1998;Fatkin et al, 1999;Phoon et al, 2000Phoon et al, , 2002Phoon et al, , 2004Ji et al, 2003;Phoon and Turnbull, 2003;Lickert et al, 2004;Mai et al, 2004;Ji and Phoon, 2005). Many of these studies have also used Doppler echocardiography, a highly sensitive method for measuring the direction and velocity of blood flow (see Phoon and Turnbull, 2003, for review).…”
Section: Ultrasound Imaging Of Mouse Developmentmentioning
confidence: 99%