Abstract: BackgroundBone conduction devices are widely used and indicated in cases of conductive, mixed or single sided deafness where conventional hearing aids are not indicated or tolerated. Percutaneous bone-conduction devices gave satisfactory hearing outcomes but were frequently complicated by soft tissue reactions. Transcutaneous bone conduction devices were developed in order to address some of the issues related to the skin-penetrating abutment. The aim of this article is to present a systematic review of the in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
43
1
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 54 publications
(45 citation statements)
references
References 22 publications
0
43
1
1
Order By: Relevance
“…The mean soft tissue thickness was 6.1 ± 1.12 mm [4-7.5]. The mean daily use was 9.4 ± 3.45 hours [4][5][6][7][8][9][10][11][12][13][14][15][16][17]. The mean strength of the SP magnet was 3 [1][2][3][4][5].…”
Section: Re Sultsmentioning
confidence: 99%
“…The mean soft tissue thickness was 6.1 ± 1.12 mm [4-7.5]. The mean daily use was 9.4 ± 3.45 hours [4][5][6][7][8][9][10][11][12][13][14][15][16][17]. The mean strength of the SP magnet was 3 [1][2][3][4][5].…”
Section: Re Sultsmentioning
confidence: 99%
“…One patient developed transient cutaneous erythema in the magnet area resolved by decreasing the magnetization force of the external magnet from 4 to 3. Cooper et al [17] described this kind of transient erythema and skin irritation in 13.1% of cases of BAHA Attract and they imputed to the pressure of the magnet on the skin and maceration. These complications are resolved quickly with the use of a smaller magnetization force [12].…”
Section: Discussionmentioning
confidence: 99%
“…The second external magnet is coupled magnetically with the processor. Many studies [9][10][11][12][13] have proven the efficiency of BAHA Attract in patients with mixed or conductive hearing loss, or single-sided sensorineural deafness has been proven in many studies and audiometric results are the same as other BCHA.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, to overcome the pitfalls associated with the use of skin‐penetrating implants, the magnetic transcutaneous systems had been introduced . However, they still have some audiological limitations.…”
Section: Introductionmentioning