2016
DOI: 10.5935/1678-9741.20160075
|View full text |Cite
|
Sign up to set email alerts
|

Abstract: ObjectiveUsually only FDA-approved oxygenators are subject of studies by the international scientific community. The objective of this study is to evaluate two types of neonatal membrane oxygenators in terms of transmembrane pressure gradient, hemodynamic energy transmission and gaseous microemboli capture in simulated cardiopulmonary bypass systems.MethodsWe investigated the Braile Infant 1500 (Braile Biomédica, São José do Rio Preto, Brazil), an oxygenator commonly used in Brazilian operating rooms, and comp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
4

Relationship

2
2

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 24 publications
(27 reference statements)
0
3
0
Order By: Relevance
“…This collaboration has improved clinical outcomes for pediatric cardiovascular patients in Brazil and other countries using the concept of translational research, modifying our practice by evidence-based research publications rather than dogmas. The choice of circuits for performing PCS with CPB is an example of this approach [ 29 , 31 - 33 ] .…”
Section: Pediatric Cardiac Surgery In the Brazilian Public Health Car...mentioning
confidence: 99%
“…This collaboration has improved clinical outcomes for pediatric cardiovascular patients in Brazil and other countries using the concept of translational research, modifying our practice by evidence-based research publications rather than dogmas. The choice of circuits for performing PCS with CPB is an example of this approach [ 29 , 31 - 33 ] .…”
Section: Pediatric Cardiac Surgery In the Brazilian Public Health Car...mentioning
confidence: 99%
“…This study was conducted at the Pediatric Cardiovascular Research Center at the Penn State Milton S. Hershey Medical Center, under the supervision and mentorship of Prof. Akif Undar [4] . The purpose of this joint venture was to understand the characteristics of a Brazilian oxygenator by using an internationally used oxygenator as a benchmark rather than to determine the superiority of one of them.…”
Section: The Importance Of Testing the Devices Used In Our Clinical Pmentioning
confidence: 99%
“…Recently, the investigators at the Heart Institute of the University of São Paulo and Penn State Health Center for Pediatric Cardiovascular Research began a collaboration to conduct translational research for neonatal and pediatric cardiac surgery patients . Usually only FDA‐approved products or products in widespread use in developed countries are objects of research by the international scientific community.…”
mentioning