2009
DOI: 10.1590/s1807-59322009001000004
|View full text |Cite
|
Sign up to set email alerts
|

A Contralateral Eye Study Comparing Apodized Diffrative and Full Diffrative Lenses: Wavefront Analysis and Distance and Near Uncorrected Visual Acuity

Abstract: PURPOSE:To evaluate intraindividual visual acuity, wavefront errors and modulation transfer functions in patients implanted with two diffractive multifocal intraocular lenses.METHODS:This prospective study examined 40 eyes of 20 cataract patients who underwent phacoemulsification and implantation of a spherical multifocal ReSTOR intraocular lens in one eye and an aspheric Tecnis ZM900 multifocal intraocular lens in the other eye. The main outcome measures, over a 3-month follow-up period, were the uncorrected … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
2

Year Published

2010
2010
2023
2023

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 14 publications
(14 citation statements)
references
References 41 publications
0
12
0
2
Order By: Relevance
“…Several studies have been performed to evaluate the best multifocal IOL diopter addition (20) . However, knowing the distance at which the patient executes most of his/her daily tasks, i.e., the patient's visual behavior, is critical for choosing an optimal IOL (27)(28)(29) . Through this unprecedented study, besides achieving a detailed medical history, we were able to add information regarding the type of patient activities performed throughout an entire day; distance estimates of patient sight; and estimates of the proportions of near, intermediate, and far sight.…”
Section: Discussion and Future Perspectivesmentioning
confidence: 99%
“…Several studies have been performed to evaluate the best multifocal IOL diopter addition (20) . However, knowing the distance at which the patient executes most of his/her daily tasks, i.e., the patient's visual behavior, is critical for choosing an optimal IOL (27)(28)(29) . Through this unprecedented study, besides achieving a detailed medical history, we were able to add information regarding the type of patient activities performed throughout an entire day; distance estimates of patient sight; and estimates of the proportions of near, intermediate, and far sight.…”
Section: Discussion and Future Perspectivesmentioning
confidence: 99%
“…Such chromatic aberration is typical for diffractive lenses including available IOLs with diffractive microrelief. 5,17,19,20 It was shown that despite relatively high chromatic aberrations, multifocal diffractive structures are widely used in commercially available refractive-diffractive IOLs, e.g., in lenses ReSTOR (Alcon Laboratories, Inc.) and Tecnis (Abbott Medical Optics, Inc.) families. In particular, the IOLs such as Tecnis ZM900 and ReSTOR SN60D3 function well in the human eye because the amount of the chromatic aberration is approximately the same, albeit with opposite sign, as the aberration in the refractive part of the eye (cornea and the refractive part of the IOL).…”
Section: Effects Of Aperture Size and Incident Wavelength Changementioning
confidence: 99%
“…In particular, the IOLs such as Tecnis ZM900 and ReSTOR SN60D3 function well in the human eye because the amount of the chromatic aberration is approximately the same, albeit with opposite sign, as the aberration in the refractive part of the eye (cornea and the refractive part of the IOL). 19,20,21 According to Eqs. (4) and (14), the energy distribution between the foci in Fig.…”
Section: Effects Of Aperture Size and Incident Wavelength Changementioning
confidence: 99%
“…-promoção de cirurgia economicamente acessível (2)(3)(4)(5)(6)(7)(8)(9) ; -oferta de cirurgia de boa qualidade, que proporcione resultados satisfatórios, utilizando novas tecnologias, e estimule a procura pelo tratamento (2,(10)(11)(12)(13)(14)(15)(16)(17)(18) .…”
Section: Importância Do Centro Cirúrgico Ambulatorial Para a Realizaçunclassified