2002
DOI: 10.1590/s1517-74912002000400012
|View full text |Cite
|
Sign up to set email alerts
|

Correlação entre grau de conversão, microdureza e conteúdo inorgânico em compósitos

Abstract: The purpose of this study was to evaluate the correlation between degree of conversion and microhardness in dental composites, as well as the effect of the inorganic content and type of photo-curing unit on these parameters. Three indirect composites (Artglass, Solidex and Zeta LC) were polymerized by means of three different laboratorial units (UniXS, Solidilite and an experimental device). For each material, fifteen samples were prepared using a metal matrix. The degree of conversion was analyzed by means of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

1
10
0
31

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(42 citation statements)
references
References 17 publications
1
10
0
31
Order By: Relevance
“…Associadas a esse fator, avaliações clínicas e laboratoriais sugerem que há associação entre o grau de conversão e as propriedades físico-mecânicas, tais como estabilidade de cor, resistência ao desgaste, à flexão ou à tração das resinas 6 . A densidade de potência emitida pelas fontes de luz deve ser no mínimo de 300 mW/cm 2 a 400 mW/cm 2 para polimerizar adequadamente um incremento de 1,5 mm a 2 mm de resina composta 1,7 .…”
Section: Introductionunclassified
See 1 more Smart Citation
“…Associadas a esse fator, avaliações clínicas e laboratoriais sugerem que há associação entre o grau de conversão e as propriedades físico-mecânicas, tais como estabilidade de cor, resistência ao desgaste, à flexão ou à tração das resinas 6 . A densidade de potência emitida pelas fontes de luz deve ser no mínimo de 300 mW/cm 2 a 400 mW/cm 2 para polimerizar adequadamente um incremento de 1,5 mm a 2 mm de resina composta 1,7 .…”
Section: Introductionunclassified
“…O percentual de duplas ligações de carbono alifáticas não convertidas (% C=C) é determinado pela taxa da intensidade de absorção entre ligações C=C (1.638 cm -1 ) e ligações C=O (1.730 cm -1 ), antes e após a polimerização. O grau de conversão correspondente é calculado pela subtração dessa taxa de 100% 6 .…”
Section: Introductionunclassified
“…The degree of conversion varies according to the composition of the materials, including monomeric systems, initiator and solvent concentration, amount and type of particles [8][9][10] .…”
mentioning
confidence: 99%
“…BRYANT, 1990;CALDAS et al, 2003;MANGA;CHARLTON;WAKEFIELD, 1995;CHUNG;GREENER, 1990;CONSANI et al, 2002;CORRER-SOBRINHO et al, 2000;VOUGIOUKLASKIS;CAPUTO, 1987;ERSOY et al, 2004;FERRACANE, 1985;FERRACANE;GREENER, 1986;HANSEN;ASMUSSEN, 1997;KANCA 3rd , 1985;KNOBLOCH et al, 2004;MANDARINO et al, 1992;MASUDA;MALUF;MUENCH, 1999;MARTINS et al, 2002;NAUFEL;NEVES et al, 2002;PERIS et al, 2005;PILO;CARDASH, 1992;PIRES et al, 1993;ANDREOU, 2004;RAMOS;GARONE NETTO;BURGER, 2003;RODE et al, 2001;RODE et al, 2005;RYGE;FOLEY;FAIRHURST, 1961;SANTOS, 2003;SAY et al, 2003;UMBEHAUN, 2001;COMBE, 1987 …”
Section: Correlação Entre Microdureza Vickers E Grau De Conversãomentioning
confidence: 99%
“…Apesar de alguns estudos não terem encontrado correlação entre a dureza e o grau de conversão (CHUNG e GREENER, 1990;VOUGIOUKLASKIS;CAPUTO, 1987). Ferracane (1985), Ferracane e Greener (1986), Neves et al (2002) e Santos (2003, mostraram haver essa correlação. A diferença nesses resultados pode ser explicada pelo fato de que, segundo Ferracane (1985) essa correlação existe quando é comparada resina composta da mesma composição e nos trabalhos onde não foi encontrada a correlação foram comparadas resinas diferentes.…”
Section: Correlação Entre Microdureza Vickers E Grau De Conversãounclassified