A poluição do ar em ambientes internos e a síndrome dos edifícios doentes

Abstract: Indoor Air Quality (IAQ) emerged as a science from the 1970s onwards with the energy crisis and the subsequent construction of sealed buildings (without natural ventilation). This mainly occurred in developed countries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
6
0
12

Year Published

2012
2012
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(18 citation statements)
references
References 13 publications
0
6
0
12
Order By: Relevance
“…Nowadays there is a continuous increase of scientific evidence that the contaminated air which is present inside a building may be more danger that the contaminated air presented outside of that same building, even in industrialized areas (Ramos, 2013). This information becomes extremely important due to the fact that a large number of people (80% to 90%) spend most of their time in buildings and consequently exposed to various existing pollutants (Schirmer, Pian, Sílvia, Szymanski, & Gauer, 2011). Environments showing a low IAQ are characterized by having a high concentration of pollutants that are harmful to the occupant's health, which are inserted into chemical parameters.…”
Section: -Theoretical Frameworkmentioning
confidence: 99%
See 1 more Smart Citation
“…Nowadays there is a continuous increase of scientific evidence that the contaminated air which is present inside a building may be more danger that the contaminated air presented outside of that same building, even in industrialized areas (Ramos, 2013). This information becomes extremely important due to the fact that a large number of people (80% to 90%) spend most of their time in buildings and consequently exposed to various existing pollutants (Schirmer, Pian, Sílvia, Szymanski, & Gauer, 2011). Environments showing a low IAQ are characterized by having a high concentration of pollutants that are harmful to the occupant's health, which are inserted into chemical parameters.…”
Section: -Theoretical Frameworkmentioning
confidence: 99%
“…These environments combined with an increase in humidity and temperature (physical parameters) can lead to the appearance of a large number of fungi and bacteria (biological parameters) (Fraga et al, 2008). These parameters have become a study base regarding the IAQ since these can be found, for example in cleaning products, materials and/or damaged equipment and polluted, due to human presence, their activities and poor conditions of ventilation and air renewal (Schirmer et al, 2011); (Alves, 2012). Due to the multiple pollutants that can be found in a building, the WHO has classified "Sick Building Syndrome" (SBS) as a danger to public health.…”
Section: -Theoretical Frameworkmentioning
confidence: 99%
“…Podendo ser comercializado na fase sólida (paraformaldeído) e como trioxano ((CH 2 O) 3 ), o formaldeído é normalmente utilizado e armazenado em solução aquosa de 30 a 50%, a qual habitualmente contém, como agente estabilizador (para evitar a polimerização), o …”
Section: Características E Fontes Emissoras Do Formaldeídounclassified
“…O interesse pelo estudo da qualidade do ar interior (QAI) surgiu após o conhecimento de que o desenvolvimento de microrganismos, o uso de produtos de limpeza, a existência de materiais e equipamentos poluentes, a própria ocupação humana e a deficiente ventilação e renovação do ar são alguns dos fatores responsáveis para que tanto o número de poluentes como a sua concentração sejam, em geral, muito mais elevados nos espaços interiores do que no ar exterior. 3,4 Este fato adquire extrema importância quando se tem em consideração que nas sociedades modernas as pessoas passam a maior parte do seu tempo no interior de edifícios (80 a 90%), inalando em média 10 m 3 de ar por dia. 5,6 A má qualidade do ar tem sido apontada como a causa de sintomas físicos e queixas, tais como dores de cabeça, irritação dos olhos e tosse.…”
Section: Introductionunclassified
“…Segundo Mendes et al (2015) micropartículas com diâmetro menor 2,5 µm podem penetrar profundamente no tecido pulmonar ocasionando redução na função do pulmão, inflamação dos alvéolos pulmonares, doenças respiratórias diversas, efeitos cardiovasculares adversos, aumento da prevalência de Doença Pulmonar Obstrutiva Crónica, e causar o stress oxidativo do DNA. Por outro lado, de modo geral, as principais doenças associadas a presença de microrganismos são o Mal dos Legionários; a febre do umidificador (doença que se desenvolve a partir de exposições a toxinas de microrganismos, especialmente daqueles que crescem nos sistemas de ventilação dos edifícios); asma brônquica; pneumonite alérgica ou alveolite extrínseca; e pneumonia (SCHIRMER et al 2011).…”
Section: Introductionunclassified