2011
DOI: 10.1590/s0103-50532011000700017
|View full text |Cite
|
Sign up to set email alerts
|

Highly selective and sensitive voltammetric sensor for captopril determination based on modified multiwall carbon nanotubes paste electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
13
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(13 citation statements)
references
References 23 publications
0
13
0
Order By: Relevance
“…Several studies highlight the use of modified electrodes for the oxidation of captopril, including carbon paste modified with p ‐aminophenol , biomimetic electrochemical sensor based on the bis (pyridyl)iron phthalocyanine (II) complex sensor based on graphene nanocomposite modified with cobalt hexacyanoferrate (II) , platinum electrode modified with iron (III) hexacyanoferrate (II) and others. Up to our knowledge, there is no record of work using ruthenium (III) hexacyanoferrate as a modifier of a glassy carbon electrode surface for determination of captopril.…”
Section: Introductionmentioning
confidence: 99%
“…Several studies highlight the use of modified electrodes for the oxidation of captopril, including carbon paste modified with p ‐aminophenol , biomimetic electrochemical sensor based on the bis (pyridyl)iron phthalocyanine (II) complex sensor based on graphene nanocomposite modified with cobalt hexacyanoferrate (II) , platinum electrode modified with iron (III) hexacyanoferrate (II) and others. Up to our knowledge, there is no record of work using ruthenium (III) hexacyanoferrate as a modifier of a glassy carbon electrode surface for determination of captopril.…”
Section: Introductionmentioning
confidence: 99%
“…Plotting the anodic peak current (inflection point current) against square root of the scan rate shows a linear correlation (see Fig. 11), which indicates that the electrochemical process is limited by the rate of diffusion 54 .…”
Section: Structure Of Carbon Nanosheetsmentioning
confidence: 94%
“…However, among the various methods reported for CP detection, electrochemical techniques are often preferred because of their low cost, high selectivity, rapid detection and their lack of a substantial sample preparation setup [14][15][16][17]. The comparisons of the proposed method for CP determination with the other electrochemical published papers are given in Table 1 [18][19][20][21][22].…”
Section: Introductionmentioning
confidence: 99%