2010
DOI: 10.1590/s0100-72032010000300003
|View full text |Cite
|
Sign up to set email alerts
|

Avaliação da maturidade pulmonar fetal pela contagem dos corpos lamelares no líquido amniótico

Abstract: The present study demonstrated that the LBND test has 100% sensitivity and higher specificity than the reference test (FP). In addition, the LBND test is considered to be rapid, accessible, inexpensive and feasible for the Brazilian reality, and it can be used as a reliable test for the prediction of fetal pulmonary maturity.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2019
2019

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…In the last decade, studies have been conducted to clarify the effectiveness of tests to determine the stage of pulmonary development, being most of them with application to the human species (Gil et al 2010). Research of this scope is scarce in veterinary medicine, and most of these data do not exist for the bovine species.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the last decade, studies have been conducted to clarify the effectiveness of tests to determine the stage of pulmonary development, being most of them with application to the human species (Gil et al 2010). Research of this scope is scarce in veterinary medicine, and most of these data do not exist for the bovine species.…”
Section: Introductionmentioning
confidence: 99%
“…The tests used to assess fetal and pulmonary maturation from amniotic fluid samples can be summarized as follows: Nile Blue Sulfate or Hematoxylin-Shorr cell staining, which indicates immaturity (Martins & Prestes 2003); test of Clements, a qualitative method that indicates the formation of a complete or incomplete bubble ring due to the saponification reaction present, whether or not there is, respectively, adequate surfactant in the amniotic fluid (Barreto et al 2011); lamellar body count, the phospholipid reservoirs, components of the pulmonary surfactant, present in the amniotic fluid, which is performed in an automatic hematological counter in the platelet count channel, due to the equivalent size of these structures (Gil et al 2010). For the lamellar body count to be applied to the bovine species, they must necessarily have the same size as the platelets, so that the hematology analyzer can perform the exam.…”
Section: Introductionmentioning
confidence: 99%