Influence of different systems of minimum ventilation on air quality in broiler houses

Abstract: ABSTRACT:To maintain a competitive development of the Brazilian aviculture, some measures must be taken to enable the identification and reduction of risks to the health of birds, as well as for the physical environment. Therefore, the aim of this study was to evaluate the effectiveness of three different systems of minimum ventilation (positive pressure -SVMP, negative pressure -SVMN and natural ventilation -SVMNat) in the air quality during the first 21 days of life of broiler chicks, during winter. Three po… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0
3

Year Published

2015
2015
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 8 publications
0
6
0
3
Order By: Relevance
“…Mean values of RH did not differ between houses; however, an interaction between the "house" and "age of broilers" factors was identified at 35 and 42 d of growth. The change in pH depends on the age of the birds, and it may be attributed to the effect of litter temperature, ambient temperature and density of birds (Pescatore et al, 2005;Menegali et al, 2012). The pH of litter also influences the release of ammonia, which is maximized at levels of pH above 7.0.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Mean values of RH did not differ between houses; however, an interaction between the "house" and "age of broilers" factors was identified at 35 and 42 d of growth. The change in pH depends on the age of the birds, and it may be attributed to the effect of litter temperature, ambient temperature and density of birds (Pescatore et al, 2005;Menegali et al, 2012). The pH of litter also influences the release of ammonia, which is maximized at levels of pH above 7.0.…”
Section: Resultsmentioning
confidence: 99%
“…The small air exchange, high humidity, temperature and pH, and type of litter management may induce greenhouse gas emissions (Menegali et al, 2012).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Com relação à saúde das aves, os valores também estão abaixo do limite recomendado por Wathes et al (1998) e Nääs et al (2007, que é de 20 ppm, sendo que, acima deste limite o animal se torna susceptível a doenças. Os valores encontrados, inferiores a 20 ppm, estão de acordo com os relatados por vários autores em diferentes tipos de galpões (Nääs et al, 2007;Vitorasso & Pereira, 2009;Furtado et al, 2010;Menegali et al, 2012).…”
Section: Resultsunclassified
“…Estes valores também são menores que o limite de 20 ppm, valor a partir do qual o animal se torna suscetível a doenças (WATHES et al, 1998;NÄÄS et al, 2007), e que corroboram os valores relatados por vários autores (NÄÄS et al, 2007;VITORASSO & PEREIRA, 2009;FURTADO et al, 2010;MENEGALI et al, 2012 …”
Section: Período Utilização De Telaunclassified