1999
DOI: 10.1590/s0100-40421999000400002
|View full text |Cite
|
Sign up to set email alerts
|

Redução seletiva aplicada à especiação de mercúrio em peixes: uma adaptação do método de Magos

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
4

Year Published

2000
2000
2018
2018

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 0 publications
0
9
0
4
Order By: Relevance
“…Devido às dificuldades na obtenção deste, utilizou-se o branco de reagentes, o que subestima o limite de detecção, já que a influência da matriz não é medida 22 . A eficiência da extração foi determinada no estudo de recuperação pela adição simultânea de padrões ao líquen P. dilatatum.…”
Section: Figura 1 Localização Geográfica Do Sítio De Amostragemunclassified
“…Devido às dificuldades na obtenção deste, utilizou-se o branco de reagentes, o que subestima o limite de detecção, já que a influência da matriz não é medida 22 . A eficiência da extração foi determinada no estudo de recuperação pela adição simultânea de padrões ao líquen P. dilatatum.…”
Section: Figura 1 Localização Geográfica Do Sítio De Amostragemunclassified
“…17 A Varian mercury hollow cathode lamp, operating at 6 mA was used as line source, at 253.7 nm. All other instrumental parameters were set as recommended by the manufacturer.…”
Section: Instrumentationmentioning
confidence: 99%
“…Microorganisms can convert Hg +2 into organomercury compounds such as methylmercury, (CH 3 )Hg + , and dimethylmercury, (CH 3 ) 2 Hg. These species are among the most dangerous environmental contaminants.…”
Section: Introductionmentioning
confidence: 99%
“…1 Therefore, proper assessment of environmental mercury contamination demands sensitive and selective analytical methods capable of speciating the several possible forms of this metal. Although procedures involving selective reduction of the analytes, coupled to detection techniques such as CV-AAS (Cold VaporAtomic Absorption Spectrometry), have been employed, 2 methodologies involving chromatographic separation of the Hg species by HPLC, 3 CE 4 or, more frequently, GC 5 are more usual. Traditionally, the ECD was the detector of choice; 6 however, since it is not specific for organomercury compounds, more recently devices such as the Atomic Emission Detector (AED) 7 have been favored.…”
Section: Introductionmentioning
confidence: 99%