2011
DOI: 10.1590/s0066-782x2011005000038
|View full text |Cite
|
Sign up to set email alerts
|

Precisão do aparelho Omron HEM-705 CP na medida de pressão arterial em grandes estudos epidemiológicos

Abstract: Background: Accurate measurement of blood pressure is of utmost importance in hypertension research. In the context of epidemiologic and clinical studies, oscillometric devices offer important advantages to overcome some of the limitations of the auscultatory method. Even though their accuracy has been evaluated in multiple studies in the clinical setting, there is little evidence of their performance in large epidemiologic studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0
2

Year Published

2011
2011
2022
2022

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 52 publications
(15 citation statements)
references
References 21 publications
0
13
0
2
Order By: Relevance
“…The measurements were performed with an Omron HEM 711 DLX automatic oscillometric sphygmomanometer, validated by the British Hypertension Society (BHS) and the Association for Advancement of Medical Instrumentation (AAMI). 21,22 A trained team collected, through a structured interview and review of medical records, information on demographic and clinical data, clinical-cardiological evaluation, history of cardiovascular events, medications, laboratory tests and factors related to lifestyle. Cardiovascular risk (CVR) was estimated by the Framingham risk score (FRS).…”
Section: Methodsmentioning
confidence: 99%
“…The measurements were performed with an Omron HEM 711 DLX automatic oscillometric sphygmomanometer, validated by the British Hypertension Society (BHS) and the Association for Advancement of Medical Instrumentation (AAMI). 21,22 A trained team collected, through a structured interview and review of medical records, information on demographic and clinical data, clinical-cardiological evaluation, history of cardiovascular events, medications, laboratory tests and factors related to lifestyle. Cardiovascular risk (CVR) was estimated by the Framingham risk score (FRS).…”
Section: Methodsmentioning
confidence: 99%
“…The accuracy of automatic blood pressure measurement is still controversial [20,21]; therefore, the mercury sphygmomanometer is considered to be the 'gold standard' for measuring blood pressure. To avoid the white-coat effect [22], the CRC will not wear a white coat during this clinical study.…”
Section: Discussionmentioning
confidence: 99%
“…Systolic and diastolic BP were taken in the left arm using an Omron automated BP cuff (HEM-711 DLX and M6 Comfort) [2628] . BP was taken after participants were seated for five minutes with an appropriately sized cuff.…”
Section: Methods and Subjectsmentioning
confidence: 99%