Abstract: A wide acceptance angle first-order reflectron lens has been incorporated into a three-dimensional atom probe ͑3DAP͒ to provide improved mass resolution. This new 3DAP instrument is capable of resolving isotopes in the mass spectrum, with resolutions better than m/⌬mϭ500 full width at half maximum and 250 full width at 10% maximum. However, use of a reflectron for energy compensation within an imaging system means that improvements in mass resolution result in degradation of the spatial resolution. This articl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
44
0

Year Published

2001
2001
2016
2016

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 168 publications
(44 citation statements)
references
References 16 publications
0
44
0
Order By: Relevance
“…APT is a unique technique able to chemically characterize the interfaces at the nanoscale and to visualize them in three dimensions [14][15][16][17] . Highly dilute impurity concentrations in the tens of ppm can be detected because of the high signal-to-noise ratio in the mass spectra.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…APT is a unique technique able to chemically characterize the interfaces at the nanoscale and to visualize them in three dimensions [14][15][16][17] . Highly dilute impurity concentrations in the tens of ppm can be detected because of the high signal-to-noise ratio in the mass spectra.…”
Section: Discussionmentioning
confidence: 99%
“…In the past two decades, Atom Probe Tomography (APT) has emerged as one of the promising nano-analytical techniques [14][15][16][17] . Until recently APT studies of solar cells have been largely restricted by difficulties in the sample preparation process and the limited capability of analyzing semiconductor materials using conventional pulsed-voltage atom probes.…”
Section: Introductionmentioning
confidence: 99%
“…APT and field-ion microscopy (FIM) experiments [25,26] were performed using conventional APT [27,28] and an Imago Scientific Instrument's LEAP tomograph [29]. Prior to conventional APT analysis, specimens were imaged at 40-50 K with FIM at background gauge pressures of neon that varied from 6.7 · 10 À4 to 2.6 · 10 À3 Pa (5 · 10 À6 to 2 · 10 À5 torr).…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, hybrid techniques of CCD readout (precise imaging) and pixel readout (precise timing) have been adopted [17], [18]. Again, the complexity of such special detector set-ups and especially the usually rather low frame rates of the CCD component require the application of alternative concepts.…”
Section: Etection Of Single Particles or Photons With A Microchannementioning