Abnormal activation of the hedgehog (Hh) signaling pathway has been found to be involved in the occurrence, invasion, and metastasis of cancers. Epithelial-mesenchymal transition (EMT) also plays an important role in the invasion and metastasis of cancers. However, the significance of the Hh signaling pathway and EMT in the invasion and metastasis of gastric cancer is still unclear. This study aimed to investigate the significance and prognostic value of the Hh signaling pathway and EMT in progressive gastric cancer. Immunohistochemistry was performed to detect the expression of the Hh-induced transcriptional factor Gli-1 and the EMT-related molecules Snail and E-cadherin in 121 patients with progressive gastric cancer. Histological type, depth of invasion, lymph node metastasis, and pTNM stage were also recorded. In progressive gastric cancer, Gli-1 expression increased markedly, and was closely associated with increased Snail expression and decreased E-cadherin expression. Diffuse type cancer, lymph node metastasis, and abnormal expression of E-cadherin were independent factors influencing the prognosis of patients with progressive gastric cancer. These findings suggest that abnormal activation of the Hh signaling pathway is closely related to the presence of EMT and is an important factor influencing the prognosis of patients with diffuse progressive gastric cancer.
BackgroundThe smartphone-based whole slide imaging (WSI) system represents a low-cost and effective alternative to automatic scanners for telepathology. In a previous study, the development of one such solution, named scalable whole slide imaging (sWSI), was presented and analyzed. A clinical evaluation of its iOS version with 100 frozen section samples verified the diagnosis-readiness of the produced virtual slides.ObjectiveThe first aim of this study was to delve into the quantifying issues encountered in the development of an Android version. It should also provide insights into future high-resolution real-time feedback medical imaging apps on Android and invoke the awareness of smartphone manufacturers for collaboration. The second aim of this study was to further verify the clinical value of sWSI with cytology samples. This type is different from the frozen section samples in that they require finer detail on the cellular level.MethodsDuring sWSI development on Android, it was discovered that many models do not support uncompressed camera pixel data with sufficient resolution and full field of view. The proportion of models supporting the optimal format was estimated in a test on 200 mainstream Android models. Other factors, including slower processing speed and camera preview freezing, also led to inferior performance of sWSI on Android compared with the iOS version. The processing speed was mostly determined by the central processing unit frequency in theory, and the relationship was investigated in the 200-model simulation experiment with physical devices. The camera preview freezing was caused by the lag between triggering photo capture and resuming preview. In the clinical evaluation, 100 ThinPrep cytology test samples covering 6 diseases were scanned with sWSI and compared against the ground truth of optical microscopy.ResultsAmong the tested Android models, only 3.0% (6/200) provided an optimal data format, meeting all criteria of quality and efficiency. The image-processing speed demonstrated a positive relationship with the central processing unit frequency but to a smaller degree than expected and was highly model-dependent. The virtual slides produced by sWSI on Android and iOS of ThinPrep cytology test samples achieved similar high quality. Using optical microscopy as the ground truth, pathologists made a correct diagnosis on 87.5% (175/200) of the cases with sWSI virtual slides. Depending on the sWSI version and the pathologist in charge, the kappa value varied between .70 and .82. All participating pathologists considered the quality of the sWSI virtual slides in the experiment to be adequate for routine usage.ConclusionsLimited by hardware and operating system support, the performance of sWSI on mainstream Android smartphones did not fully match the iOS version. However, in practice, this difference was not significant, and both were adequate for digitizing most of the sample types for telepathology consultation.
INTRODUCTION: Endoscopic biliary brushing is the most common method used for sampling in patients with malignant biliary strictures (MBSs); however, its sensitivity is relatively low. There is still no consensus on endoscopy-based biliary brushing, although brushing 10 times in 1 specimen is routinely performed. This study was designed to compare the sensitivity of brush cytology for 10, 20, or 30 brushing times of a pass in 1 specimen in patients with MBSs.
The grade of LVSI is an important predictive factor for disease recurrence and poor survival of patients with epithelial ovarian carcinoma.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.