AimsCardiovascular magnetic resonance (CMR) allows non-invasive phase contrast measurements of flow through planes transecting large vessels. However, some clinically valuable applications are highly sensitive to errors caused by small offsets of measured velocities if these are not adequately corrected, for example by the use of static tissue or static phantom correction of the offset error. We studied the severity of uncorrected velocity offset errors across sites and CMR systems.Methods and ResultsIn a multi-centre, multi-vendor study, breath-hold through-plane retrospectively ECG-gated phase contrast acquisitions, as are used clinically for aortic and pulmonary flow measurement, were applied to static gelatin phantoms in twelve 1.5 T CMR systems, using a velocity encoding range of 150 cm/s. No post-processing corrections of offsets were implemented. The greatest uncorrected velocity offset, taken as an average over a 'great vessel' region (30 mm diameter) located up to 70 mm in-plane distance from the magnet isocenter, ranged from 0.4 cm/s to 4.9 cm/s. It averaged 2.7 cm/s over all the planes and systems. By theoretical calculation, a velocity offset error of 0.6 cm/s (representing just 0.4% of a 150 cm/s velocity encoding range) is barely acceptable, potentially causing about 5% miscalculation of cardiac output and up to 10% error in shunt measurement.ConclusionIn the absence of hardware or software upgrades able to reduce phase offset errors, all the systems tested appeared to require post-acquisition correction to achieve consistently reliable breath-hold measurements of flow. The effectiveness of offset correction software will still need testing with respect to clinical flow acquisitions.
An efficient nonrigid registration algorithm was implemented on the image reconstruction computer to enable in-line automatic tracking of features in steady-state free precession cine images. Four-dimensional left ventricle function analysis was performed with and without use of the in-line automatic tracking result. The method was tested in 30 patients referred for cardiac magnetic resonance imaging for a variety of clinical assessments. The time required for in-line tracking was 10 +/- 2 s per slice using an image reconstructor with dual Advanced Micro Devices single-core Opteron 248 CPUs (2.2 GHz) and 8GB random access memory. The precision of clinical estimates of left ventricular volumes was significantly improved relative to the ground truth research estimates with automatic tracking versus without (6 ml vs. 9 ml in end-diastolic volume; 5 ml vs. 10 ml in end-systolic volume; both p < 0.05). In-line automatic tracking of image features shows promise for facilitating clinical analysis of ventricular function.
Background/Aims: Lung cancer is the leading cause of cancer-related deaths worldwide. The outcome of patients with non-small cell lung cancer remains poor; the 5-year survival rate for stage IV non-small cell lung cancer is only 1.0%. KIF15 is a tetrameric kinesin spindle motor that has been investigated for its regulation of mitosis. While the roles of kinesin motor proteins in the regulation of mitosis and their potentials as therapeutic targets in pancreatic cancer have been described previously, the role of KIF15 in lung cancer development remains unknown. Methods: Paired lung carcinoma specimens and matched adjacent normal tissues were used for protein analysis. Clinical data were obtained from medical records. We first examined KIF15 messenger RNA expression in The Cancer Genome Atlas database, and then determined KIF15 protein levels using immunohistochemistry and western blotting. Differences between the groups were analyzed using repeated measures analysis of variance. Overall survival was analyzed using the Kaplan–Meier method. Cell-cycle and proliferation assays were conducted using A549, NCI-H1299, and NCI-H226 cells. Results: KIF15 was significantly upregulated at both the messenger RNA and protein levels in human lung tumor tissues. In patients with lung adenocarcinoma, KIF15 expression was positively associated with disease stages; high KIF15 expression predicted a poor prognosis. KIF15 knockdown using short hairpin RNA in two human lung adenocarcinoma cell lines induced G1/S phase cell cycle arrest and inhibited cell growth, but there was no effect in human lung squamous cell carcinoma. Conclusion: Our findings show that KIF15 is involved in lung cancer carcinogenesis. KIF15 could therefore serve as a specific prognostic marker for patients with lung adenocarcinoma.
Abstract1q21 gain is a common cytogenetic abnormality featuring high‐risk multiple myeloma (HRMM). However, the molecular mechanism underlying the adverse prognostic effect of 1q21 gain remains largely unclear. Here, we report that ARNT/HIF‐1β, a 1q21 gene, is highly expressed in HRMM and induced by microenvironmental hypoxia, which confers drug resistance and correlates with inferior outcome. Analysis of the gene expression profile database revealed that ARNT expression was upregulated in MM and increased with disease progression or in HRMM subtypes (particularly 1q21 gain), while correlated to shorter overall survival. In a cohort of 40 MM patients, qPCR further validated that ARNT expression was higher in MM patients than normal donors. MM cells carrying 1q21 gain or acquired drug resistance displayed a robust increase in HIF‐1β protein level. Hypoxia induced HIF‐1β expression via a NF‐κB‐dependent process. Notably, HIF‐1β overexpression impaired bortezomib sensitivity, whereas shRNA knockdown of ARNT reversed hypoxia‐mediated drug resistance. Together, these findings suggest that ARNT/HIF‐1β might represent a novel biomarker for risk stratification and prognosis of HRMM patients, as well as a potential therapeutic target for overcoming 1q21 gain‐ or microenvironment‐mediated and acquired drug resistance in MM.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.