BackgroundThe purpose of this study was to compare the clinical outcomes of elderly patients undergoing surgery for treatment of unstable trochanteric fractures receiving either proximal femoral nails anti-rotation-Asia (PFNA-IIs) or InterTan nails (ITs).MethodsBetween January 1, 2012, and June 31, 2015, 168 elderly patients with unstable intertrochanteric femur fractures enrolled in this study. The only intervention was ITs or PFNA-IIs of the unstable trochanteric femur fractures. Follow-up was at 1, 3, 6, and 12 months postoperatively and yearly thereafter. Intraoperative variables and postoperative complications were compared between the two groups.ResultsEight patients died, six were too infirmed for follow-up, and seven were lost during follow-up, leaving 147 patients meeting the criteria were evaluated at a mean follow-up of 20 months (range 16–26 months). Significant differences were observed between the two groups regarding local complications (IT, n = 10 vs. PFNA-II, n = 20), varus collapse of the head/neck or femoral shaft fractures at the tip of the nail (IT, n = 1 vs. PFNA-II, n = 8), femoral neck shortening (IT, 4.4 ± 1.1 mm vs. PFNA-II, 7.4 ± 2.4 mm), fracture healing time (IT, 14.7 ± 2.1 weeks vs. PFNA-II, 15.7 ± 2.4 weeks), femoral shaft fractures (IT, n = 0 vs. PFNA-II, n = 4), rotational loss of reduction (IT, n = 0 vs. PFNA-II, n = 9), lateral cortex fractures of the proximal femur or lateral greater trochanter fractures (IT, n = 8 vs. PFNA-II, n = 1), operative time (IT, 71.9 ± 6.8 min vs. PFNA-II, 52.3 ± 4.0 min), intraoperative blood loss (IT, 190.6 ± 6.0 mL vs. PFNA-II, 180.9 ± 10.8 mL), fluoroscopy time (IT, 5.0 ± 0.48 min vs. PFNA-II, 2.8 ± 0.33 min), hospital stay (IT, 9.65 ± 0.95 days vs. PFNA-II, 8.58 ± 0.93 days), cut-out (IT, n = 0 vs. PFNA-II, n = 6), and tip-apex distance (IT, 26.7 ± 0.91 mm vs. PFNA-II, 23.2 ± 1.22 mm). No significant differences existed for the other observation indexes (p > 0.05).ConclusionsThe IT nail may have more advantage for patients with unstable intertrochanteric fractures of the femur. However, for those complicated with lateral greater trochanter fractures, lateral cortex fractures of the proximal femurs, or unfit for surgery, the PFNA-II nail could be a good option. In addition, a large-sample, multicenter observational study is required for evaluation of its long-term efficacy, and optimal management strategies for specific unstable fracture patterns, different sorts of bone quality, and different levels of patient demand.
BackgroundConversion to total hip arthroplasty (CTHA) is a relatively common procedure after a failed dynamic hip screw (DHS) or proximal femoral nail anti-rotation (PFNA) fixation of intertrochanteric fractures, but there have been far fewer reports specifically describing the long-term results of CTHA after failed treatments of stable intertrochanteric fractures with DHS or PFNA. The aim of the present study was to compare the clinical and radiological outcomes of CTHA after failed PFNA or DHS fixations of stable intertrochanteric fractures after a minimum follow-up of 3 years.MethodsBetween January 2005 and April 2014, we retrospectively reviewed 142 active elderly patients treated at our institution (a single institution study). A total of 72 patients (72 hips; 41 women, 31 men; mean age 76.9 years old; range 60–92 years old) who underwent conversion of a failed PFNA to a THA were compared with 70 patients (70 hips; 36 women, 34 men; mean age 75.0 years old; range 60–90 years old) who underwent CTHA after a failed DHS fixation. The mean follow-up periods were 48 (range 43–52) and 48 (range 44–52) months for the DHS and PFNA groups, respectively. Clinical and radiologic evaluations were performed on all patients. The primary outcome was the Harris Hip Score (HHS). The secondary outcomes were the complication rates.ResultsThe Harris Hip Score (HHS) improved from 50.61 ± 3.23 preoperatively to 85.28 ± 4.45 at the last follow-up in the PFNA group and from 51.46 ± 3.90 to 84.50 ± 4.34 in the DHS group, with no significant differences noted between the groups at each follow-up (P > 0.05). However, the complication rate in the converted DHS patients was significantly higher (42.9%) than that in the converted PFNA patients (20.8%; P = 0.003). Thirty-seven PFFs (2.4%) occurred during a mean follow-up of 44.4 months. The incidence of periprosthetic fractures was found to be significantly higher (P = 0.021) for the DHS group (15.7%) than for the PFNA group (4.2%).ConclusionsCTHA after failed DHS fixations of stable intertrochanteric fractures might be associated with a significantly higher complication rate than CTHA after failed PFNA fixations. Therefore, PFNA patients with stable intertrochanteric fractures may be more suitable for CTHA.
BackgroundDynamic hip screws (DHSs) and proximal femoral nails anti-rotation (PFNAs) are well-documented implants for stable intertrochanteric femur fractures(IFFs); however, there is no consensus regarding which type of implant is the better option for stable IFFs. This study aimed to compare DHSs with PFNAs in the management of stable intertrochanteric fractures.MethodsA retrospective study was performed in our institution. Between June, 2005 and November, 2015, 267 patients (267 hips) with stable IFFs (AO/OTA Type 3.1A1) were treated with a DHS or a PFNA. Inclusion and exclusion criteria were designed to focus on isolated stable IFFs in ambulatory patients. Follow-up was undertaken at 1, 3, 12, 15, 18, 21, 24, 36, 48 postoperative months, and at final follow-up. Radiograph outcomes were obtained at all visits. The primary outcome measure was re-operation rate. The secondary outcome was patient function, evaluated using Harris hip score (HHS). Tertiary outcomes included: intra- and post-operative orthopaedic complications.ResultsTwo hundred twenty two patients (110 in the PFNA group and 112 in the DHS group) were evaluated with a mean follow-up period of 53 months (range, 48–60 months). There was an increased risk of reoperation after DHS in one-year follow-up: 0 % and 5.4 % for PFNA and DHS, respectively (P = 0.029). The difference persisted with time: 6.4 % and 13.4 % at last follow-up (P < 0.05). There are statistical differences in postoperative HHS at 12, 15, 18, 21, 24, 36, 48 months postoperatively and at final follow-up. No statistical differences in medical complications was observed between the two groups. The orthopaedic complications were more in the DHS group (n = 42) compared with the PFNA group (n = 18) (P <0.05).ConclusionCompared with PFNA device, DHS device might not be the preferred implant for stable intertrochanteric femur fractures.
BackgroundThe study aims to compare the long-term functional and radiographic outcomes of two devices for the treatment of primary intertrochanteric fractures (IFs, OTA 3.1A2.1–A2.3) in elderly patients with osteoporosis.MethodsBetween December 2010 and August 2014, 332 elderly osteoporosis patients with IFs (OTA 3.1A2.1–A2.3) fixed by an InterTAN nail (IT) or a proximal femoral nail anti-rotation (PFNA) device were retrospectively evaluated. Follow-up occurred 1, 3, 6, and 12 months postoperatively and every year thereafter. Mortality was recorded. Patient-related functional and radiographic outcomes were compared. The primary endpoint was the long-term radiographic outcomes. The secondary endpoint was the long-term functional outcomes.ResultsA total of 283 patients (283 hips) with osteoporosis (IT, n = 144; PFNA, n = 139) were evaluated with a mean follow-up period of 38.8 months (range, 36–43 months). No between-group significant differences were noted in the patient demographics, operation variables, and postoperative Harris Hip Score. More radiographic complications were noted in terms of screw cut-out, femoral shaft fracture distal or around the tip of the main nail, and varus collapse of the femoral head in the PFNA group compared with that in the IT group (P < 0.05).ConclusionFor osteoporotic IFs (OTA 3.1A2.1–A2.3) in elderly patients, the use of IT aids in decreasing radiographic complications, but the between-group functional outcomes showed no significant difference.
Breast cancer is the most frequent malignancy in women worldwide, and triple-negative breast cancer (TNBC) patients have the worst prognosis and highest risk of recurrence. The therapeutic strategies for TNBC are limited. It is urgent to develop new methods to enhance the efficacy of TNBC treatment. Previous studies demonstrated that D-mannose, a hexose, can enhance chemotherapy in cancer and suppress the immunopathology of autoimmune diseases. Here, we show that D-mannose can significantly facilitate TNBC treatment via degradation of PD-L1. Specifically, D-mannose can activate AMP-activated protein kinase (AMPK) to phosphorylate PD-L1 at S195, which leads to abnormal glycosylation and proteasomal degradation of PD-L1. D-mannose–mediated PD-L1 degradation promotes T cell activation and T cell killing of tumor cells. The combination of D-mannose and PD-1 blockade therapy dramatically inhibits TNBC growth and extends the lifespan of tumor-bearing mice. Moreover, D-mannose–induced PD-L1 degradation also results in messenger RNA destabilization of DNA damage repair–related genes, thereby sensitizing breast cancer cells to ionizing radiation (IR) treatment and facilitating radiotherapy of TNBC in mice. Of note, the effective level of D-mannose can be easily achieved by oral administration in mice. Our study unveils a mechanism by which D-mannose targets PD-L1 for degradation and provides methods to facilitate immunotherapy and radiotherapy in TNBC. This function of D-mannose may be useful for clinical treatment of TNBC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.