There has been recent interest in the relationship between socioeconomic status and the diagnosis of autism in children. Studies in the US have found lower rates of autism diagnosis associated with lower socioeconomic status, while studies in other countries report no association, or the opposite. This paper aims to contribute to the understanding of this relationship in the UK. Using data from the Born in Bradford cohort, comprising of 13,857 children born between 2007 and 2011, it was found that children of mothers educated to A-level or above had twice the rate of autism diagnosis, 1.5% of children (95% CI: 1.1%, 1.9%) compared to children of mothers with lower levels of education status 0.7% (95% CI: 0.5%, 0.9%). No statistically significant relationship between income status or neighbourhood material deprivation was found after controlling for mothers education status. The results suggest a substantial level of underdiagnosis for children of lower education status mothers, though further research is required to determine the extent to which this is replicated across the UK. Tackling inequalities in autism diagnosis will require action, which could include increased education, awareness, further exploration of the usefulness of screening programmes, and the provision of more accessible support services.
The worldwide prevalence of Parkinson's disease is increasing. There is urgent need for new tools to objectively measure the condition. Existing methods to record the cardinal motor feature of the condition, bradykinesia, using wearable sensors or smartphone apps have not reached large-scale, routine use. We evaluate new computer vision (artificial intelligence) technology, DeepLabCut, as a contactless method to quantify measures related to Parkinson's bradykinesia from smartphone videos of finger tapping. MethodsStandard smartphone video recordings of 133 hands performing finger tapping (39 idiopathic Parkinson's patients and 30 controls) were tracked on a frame-by-frame basis with DeepLabCut. Objective computer measures of tapping speed, amplitude and rhythm were correlated with clinical ratings made by 22 movement disorder neurologists using the Modified Bradykinesia Rating Scale (MBRS) and Movement Disorder Society revision of the Unified Parkinson's Disease Rating Scale (MDS-UPDRS). ResultsDeepLabCut reliably tracked and measured finger tapping in standard smartphone video. Computer measures correlated well with clinical ratings of bradykinesia (Spearman coefficients): -0.74 speed, 0.66 amplitude, -0.65 rhythm for MBRS; -0.56 speed, 0.61 amplitude, -0.50 rhythm for MDS-UPDRS; 0.69 combined for MDS-UPDRS. All p < 0.001. ConclusionNew computer vision software, DeepLabCut, can quantify three measures related to Parkinson's bradykinesia from smartphone videos of finger tapping. Objective 'contactless' measures of standard clinical examinations were not previously possible with wearable sensors (accelerometers, gyroscopes, infrared markers).DeepLabCut requires only conventional video recording of clinical examination and is entirely 'contactless'. This next generation technology holds potential for Parkinson's and other neurological disorders with altered movements.
FCH-PET/CT has the potential to impact on the management of patients with prostate cancer significantly more often than CI.
We present the results of a pilot study designed to investigate methods that may be applied to develop a patient position correction protocol for the post-prostatectomy patient receiving radiotherapy. Imaging was carried out with cone beam CT (CBCT) to investigate its suitability for detecting changes in rectal and bladder volumes and movements of these organs relative to the treatment planning CT. Eligible patients were imaged daily during the first week of treatment and weekly thereafter. Surrogate explanatory variables, including distance from the isocentre to the anterior rectum and bladder length, were tested for their potential to substitute for contouring entire organs and predict for changes in coverage of the planning treatment volume (PTV) by the 95% isodose (PTV95) and the maximum dose delivered to 50% of the rectal volume (RECTD50). The PTV defined on the CBCT images was larger than that defined on the planning CT and resulted in a decrease in the PTV95. Bladder length correlated with bladder volume and changes in bladder volume were associated with a decrease in PTV95. Rectal volumes changed randomly during treatment. There was a trend for the rectum to move anteriorly as treatment progressed. CBCT may be used to define the PTV, rectum and bladder though the reason for an apparent increase in PTV on CBCT requires further investigation. The bladder length and distance to the anterior rectal wall are potential surrogate explanatory variables. Further studies will be designed to test values of these surrogates that predict the need for a change in isocentre position.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.