Background:Perianal fistula is a commonly encountered condition in routine surgical practice. Accurate presurgical mapping of these tracts is vital to prevent recurrence. We have assessed the effectiveness of percutaneous instillation of aqueous jelly prior to magnetic resonance (MR) fistulography.Aims and Objectives:To study the role of percutaneous instillation of aqueous jelly in fistulous tracts prior to MR fistulography.Materials and Methods:All patients with active discharge, referred for MR fistulography between January 2014 and April 2016, were included in this study. Approximately 3–5 ml of sterile aqueous jelly was percutaneously instilled into the external openings prior to MR fistulography. Post MR fistulography, patients were monitored till surgery for pain, fever, or bleeding. The type of fistulae, location of internal openings, lateral ramifications, and presence of abscess were compared with per operative findings for diagnostic accuracy.Results:Sixty-four patients enrolled in our study had undergone preoperative MR fistulography with aqueous jelly instillation. MR fistulography revealed a total of 77 tracts and showed a sensitivity and specificity of 100% in delineation of type of tract. Forty-nine internal openings were identified with 94.2% sensitivity, 100% specificity, and 95.3% accuracy. 90.5% sensitivity, 100% specificity, and accuracy of 97% were observed in delineation of lateral ramifications. None of the patients reported pain, fever, or bleeding post procedure till surgery.Conclusion:Percutaneous instillation of aqueous jelly prior to MR fistulography is a safe, cost effective, and accurate technique to provide a comprehensive delineation of the complex anatomy of perianal fistulae.
Objective: To examine internal organ tissues and placentas of stillbirths for various pathogens. Design: Prospective, observational study. Settings: Three study hospitals in India and a large maternity hospital in Pakistan. Population: Stillborn infants delivered in a study hospital. Methods: A prospective observational study. Main outcome measures: Organisms identified by pathogen polymerase chain reaction (PCR) in internal organs and placental tissues of stillbirths.Results: Of 2437 stillbirth internal tissues, 8.3% (95% CI 7.2-9.4) were positive. Organisms were most commonly detected in brain (12.3%), cerebrospinal fluid (CSF) (9.5%) and whole blood (8.4%). Ureaplasma urealyticum/parvum was the organism most frequently detected in at least one internal organ (6.4% of stillbirths and 2% of all tissues). Escherichia coli/Shigella was the next most common (4.1% one or more internal organ tissue sample and 1.3% of tissue samples), followed by Staphylococcus aureus in at least one internal organ tissue (1.9% and 0.9% of all tissues). None of the other organisms was found in more than 1.4% of the tissue samples in stillbirths or more than 0.6% of the internal tissues examined. In the placenta tissue, membrane or cord blood combined, 42.8% (95% CI 40.2-45.3) had at least one organism identified, with U. urealyticum/parvum representing the most commonly identified (27.8%). Conclusions: In about 8% of stillbirths, there was evidence of a pathogen in an internal organ. Ureaplasma urealyticum/parvum was the most common organism found in the placenta and in the internal tissues, especially in the fetal brain.
Context:Ultrasonography of thyroid gland is a frequently performed investigation. Many of the diffuse thyroid pathologies are associated with altered vascularity. In view of potential applications and scant available data, there is a need to find normal values of Doppler indices of superior thyroid artery (STA).Aims:To find the normal range of Doppler indices like mean peak systolic velocity (PSV), resistivity index (RI), and pulsatility index (PI) of STA in clinically euthyroid adult individuals.Settings and Design:Prospective cross-sectional observational study.Materials and Methods:A study was done in the Department of Radiodiagnosis of a tertiary care hospital, involving clinically euthyroid adult volunteers. Ultrasonography of the thyroid gland with Doppler of bilateral STAs was performed and mean values of PSV, RI, and PI were calculated.Results:A total of 208 subjects, with a mean age of 37.7 years, underwent Doppler evaluation of STA; 148 of them were women and 60 were men. The mean PSV obtained was 16.94 ± 5.3 cm/s. Mean PI and RI were 0.93 ± 0.31 and 0.5 ± 0.13, respectively. There was no significant difference in the values obtained among both the genders.Conclusion:Mean values of Doppler indices of STA in euthyroid individuals have been found in this study.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.