Confocal spectroscopic techniques are applied to selected Raman bands to study the microscopic features of acetabular cups made of ultra-high molecular weight polyethylene (UHMWPE) before and after implantation in vivo. The micrometric lateral resolution of a laser beam focused on the polymeric surface (or subsurface) enables a highly resolved visualization of 2-D conformational population patterns, including crystalline, amorphous, orthorhombic phase fractions, and oxidation index. An optimized confocal probe configuration, aided by a computational deconvolution of the optical probe, allows minimization of the probe size along the in-depth direction and a nondestructive evaluation of microstructural properties along the material subsurface. Computational deconvolution is also attempted, based on an experimental assessment of the probe response function of the polyethylene Raman spectrum, according to a defocusing technique. A statistical set of high-resolution microstructural data are collected on a fully 3-D level on gamma-ray irradiated UHMWPE acetabular cups both as-received from the maker and after retrieval from a human body. Microstructural properties reveal significant gradients along the immediate material subsurface and distinct differences are found due to the loading history in vivo, which cannot be revealed by conventional optical spectroscopy. The applicability of the confocal spectroscopic technique is valid beyond the particular retrieval cases examined in this study, and can be easily extended to evaluate in-vitro tested components or to quality control of new polyethylene brands. Confocal Raman spectroscopy may also contribute to rationalize the complex effects of gamma-ray irradiation on the surface of medical grade UHMWPE for total joint replacement and, ultimately, to predict their actual lifetime in vivo.
We aim to establish a confocal spectroscopic technique able to study the features of fluorescence spectra arising from native Cr3+ impurity in polycrystalline alumina (Al2O3) as a biomaterial and to use their emission lines as microscopic probes for the characterization of residual stress fields stored in artificial hip prostheses during their implantation in vivo. As an application of the technique, we report for the first time concerning the evolution of microscopic (residual) stress fields stored on the surface and in the subsurface of N=7 retrieved Al2O3 hip joints after exposure in the human body from a few months to 19 yr. The micrometric diameter of the laser beam waist impinging on the joint surface (typically about 1 microm in lateral resolution) enables us to estimate the patterns and magnitude of residual stress with high spatial resolution, at least comparable with the grain size of the material. In addition, a selected confocal configuration for the optical probe enables minimization of the probe size along the in-depth direction. According to a statistical collection of data on the microscopic level for retrieved femoral heads in toto, a residual stress field arising from loading history in vivo during the lifetime of the Al2O3 femoral head can be revealed. Finally, an interpretation is given of microscopic wear mechanisms in Al2O3 artificial hip joints consistent with the observed evolution of surface residual stress fields on elapsed time in vivo.
Morphology and design of ultra-high molecular weight polyethylene (UHMWPE or simply PE) acetabular components used in total hip arthroplasty (THA) have been evolving for more than half a century. Since the late-1990s, there were two major technological innovations in PE emerged from necessity to overcome the wear-induced periprosthetic osteolysis, i.e., the development of highly crosslinked PEs (HXLPEs). There are many literature reporting that radiation crosslinked and remelted/annealed (first-generation) HXLPEs markedly reduced the incidence of osteolysis and aseptic loosening. Regardless of such clinical success in the first-generation technologies, there were some recent shifts in Japan toward the use of new second-generation HXLPEs subjected to sequential irradiation/annealing or antioxidant vitamin E (α-tocopherol) incorporation. Although the selection rate of first-generation liners still account for more than half of all the PE THAs (∼58% in 2015), the use of vitamin E-stabilized liners has been steadily growing each year since their clinical introduction in 2010. In these contexts, it is of great importance to evaluate and understand the real clinical benefits of using the new second-generation liners as compared to the first generation. This article first summarizes structural evolution and characteristic features of first-generation HXLPEs, and then provides a detailed description of second-generation antioxidant HXLPEs in regard to the role of vitamin E incorporation on their chemical and mechanical performances in THA.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.