This is the accepted version of the paper.This version of the publication may differ from the final published version. Abstract-Dielectric response measurement techniques in both time and frequency domains are studied in order to measure the dielectric loss of XLPE cables, which have very low losses. A high sensitivity transformer ratio bridge system, which can measure loss tangents as low as 10 -5 , has been developed with the ability to measure these cables. A tuned amplifier was designed to help to extend the frequency range from 200Hz to 20kHz. Different model cables from Borealis AB with different semiconducting materials have been measured in the temperature range 15⁰C to 120⁰C. It is found that the semiconducting layers dominate the dielectric loss in the insulation system of the XLPE cables, when the outer semicon is treated as measuring electrode. In this case, steadily increasing dielectric loss has been measured at higher frequencies. The resistivity of the semiconducting materials was measured, which confirmed that the increasing slope is due to the semiconducting layers. After using conductive tapes to wrap the cable samples, monotonically decreasing losses were measured, corresponding to the actual dielectric frequency response of the XLPE cables. It is concluded that the axial resistance of semiconducting shields have a substantial influence on the dielectric loss of XLPE cables, especially for dielectric response in high frequency range. A device on measuring the loss of such cables is presented. Permanent repository link
F. (2010). Dielectric spectroscopy study of thermally-aged extruded model power cables. 2010 10th IEEE International Conference on Solid Dielectrics (ICSD), pp. 1-4. doi: 10.11091-4. doi: 10. /ICSD.2010 This is the accepted version of the paper.This version of the publication may differ from the final published version. Abstract-"Model" extruded power cables, having a much reduced geometry but using the same extrusion techniques and materials as full-sized cables, have been examined using dielectric spectroscopy techniques to study their thermal ageing effects. Cables insulated with homo-polymer XLPE and co-polymer of XLPE with micron-sized ethylene-butyl-acrylate (EBA) islands were studied by both frequency-domain and time-domain dielectric spectroscopy techniques after accelerated thermal ageing under 135°C for 60 days. In the frequency domain, a frequency response analyzer (FRA) was used to measure the frequency range from 10 -4 Hz to 1Hz at temperatures from 20C to 80C. In the time domain, a special charging/discharging current measurement system was developed to measure the frequencies from 10 -1 Hz to 10 2 Hz. These techniques were chosen to cope with the extremely low dielectric losses of the model cables. The results are compared with those from new model power cables that were degassed at 80°C for 5 days. Thermal ageing was found to increase the low-frequency conductivity, permittivity and the discharging current. Both homo-and copolymer cables have substantial increase of dielectric loss after ageing. Permanent
scite is a Brooklyn-based startup that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2023 scite Inc. All rights reserved.
Made with 💙 for researchers