A new x-ray source, the model S700 Axxent X-Ray Source (Source), has been developed by Xoft Inc. for electronic brachytherapy. Unlike brachytherapy sources containing radionuclides, this Source may be turned on and off at will and may be operated at variable currents and voltages to change the dose rate and penetration properties. The in-water dosimetry parameters for this electronic brachytherapy source have been determined from measurements and calculations at 40, 45, and 50 kV settings. Monte Carlo simulations of radiation transport utilized the MCNP5 code and the EPDL97-based mcplib04 cross-section library. Inter-tube consistency was assessed for 20 different Sources, measured with a PTW 34013 ionization chamber. As the Source is intended to be used for a maximum of ten treatment fractions, tube stability was also assessed. Photon spectra were measured using a high-purity germanium (HPGe) detector, and calculated using MCNP. Parameters used in the two-dimensional (2D) brachytherapy dosimetry formalism were determined. While the Source was characterized as a point due to the small anode size, < 1 mm, use of the one-dimensional (1D) brachytherapy dosimetry formalism is not recommended due to polar anisotropy. Consequently, 1D brachytherapy dosimetry parameters were not sought. Calculated point-source model radial dose functions at gP(5) were 0.20, 0.24, and 0.29 for the 40, 45, and 50 kV voltage settings, respectively. For 1
Although a multicenter, Phase III, prospective, randomized trial is the gold standard for evidence-based medicine, it is rarely used in the evaluation of innovative devices because of many practical and ethical reasons. It is usually sufficient to compare the dose distributions and dose rates for determining the equivalence of the innovative treatment modality to an existing one. Thus, quantitative evaluation of the dosimetric characteristics of innovative radiotherapy devices or applications is a critical part in which physicists should be actively involved. The physicist's role, along with physician colleagues, in this process is highlighted for innovative brachytherapy devices and applications and includes evaluation of (1) dosimetric considerations for clinical implementation (including calibrations, dose calculations, and radiobiological aspects) to comply with existing societal dosimetric prerequisites for sources in routine clinical use, (2) risks and benefits from a regulatory and safety perspective, and (3) resource assessment and preparedness. Further, it is suggested that any developed calibration methods be traceable to a primary standards dosimetry laboratory (PSDL) such as the National Institute of Standards and Technology in the U.S. or to other PSDLs located elsewhere such as in Europe. Clinical users should follow standards as approved by their country's regulatory agencies that approved such a brachytherapy device. Integration of this system into the medical source calibration infrastructure of secondary standard dosimetry laboratories such as the Accredited Dosimetry Calibration Laboratories in the U.S. is encouraged before a source is introduced into widespread routine clinical use. The American Association of Physicists in Medicine and the Groupe Européen de Curiethérapie-European Society for Radiotherapy and Oncology (GEC-ESTRO) have developed guidelines for the safe and consistent application of brachytherapy using innovative devices and applications. The current report covers regulatory approvals, calibration, dose calculations, radiobiological issues, and overall safety concerns that should be addressed during the commissioning stage preceding clinical use. These guidelines are based on review of requirements of the U.S. Nuclear Regulatory Commission, U.S. Department of Transportation, International Electrotechnical Commission Medical Electrical Equipment Standard 60601, U.S. Food and Drug Administration, European Commission for CE Marking (Conformité Européenne), and institutional review boards and radiation safety committees.
Low-energy x-rays are known to have a higher relative biological effectiveness (RBE) than higher energy photons such as the gamma rays from 192Ir and 60Co. In this work the initial yield of single- and double-strand DNA breaks (SSB and DSB) and the RBE was estimated for a novel electronic brachytherapy source (EBS), emitting 40-50 kVp photons. An EGSnrc Monte Carlo model of the source was used in combination with the 'Monte Carlo damage simulation' program (Semenenko and Stewart 2004 Radiat. Res. 161 451-57; 2006 Phys. Med. Biol. 51 1693-706). The results indicate a substantially reduced SSB yield and increased DSB yield for the EBS compared to 60Co or 192Ir, leading to an enhanced RBE by 40-50%. The RBE estimate for the low-energy x-ray EBS was found to be very similar to the low-energy gamma ray brachytherapy isotope 125I. Biological damage was estimated in several human tissues: muscle, breast, calcified breast and cortical bone. SSB and DSB yields were similar in all media, except in bone. These findings should be taken into account if the EBS is intended to replace brachytherapy with the commonly used 192Ir isotope.
Early experience demonstrates that the electronic brachytherapy system performed as expected. Electronic brachytherapy has similar acute toxicity profiles to other high dose rate approaches for accelerated partial breast irradiation and offers the convenience of having the treatment in an unshielded room.
The Axxent developed by Xoft Inc. is a novel electronic brachytherapy system capable of generating x-rays up to 50 keV. These low energy photon-emitting sources merit attention not only because of their ability to vary the dosimetric properties of the radiation, but also because of the radiobiological effects of low energy x-rays. The objective of this study is to characterize the x-ray source and to model it using the Geant4 Monte Carlo code. Spectral and attenuation curve measurements are performed at various peak voltages and angles and the source is characterized in terms of spectrum and half-value layers (HVLs). Also, the effects of source variation and source aging are quantified. Bremsstrahlung splitting, phase-space scoring and particle-tagging features are implemented in the Geant4 code, which is bench-marked against BEAMnrc simulations. HVLs from spectral measurements, attenuation curve measurements and Geant4 simulations mostly agree within uncertainty. However, there are discrepancies between measurements and simulations for photons emitted on the source transverse plane (90 degrees).
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.