Spring-back closure occurred in 10% of our patients at or before 6 months after surgery. The incidence of spring-back by level (ie, 117 laminae) was 6%, mainly occurring at the lower cervical spine. All spring-back closures were partial segmental closures, most commonly involving C5 and C6. Postoperative neurologic deficit was associated with spring-back closure; therefore, surgeons should adopt preemptive surgical measures to prevent the occurrence of such a complication.
Vertebral body lavage prior to cement augmentation is a safe technique to reduce cement leakage in a clinical setting and has the potential to prevent pulmonary fat embolism. Moreover, a better filling pattern can be achieved.
Borderline subluxated hips and those with marked coxa valga and/or acetabular dysplasia should be closely monitored to determine the need for surgery in the future. Subluxated hips should be operated on early, particularly in children and symptomatic adults.
We conclude that the smart phone with integrated Tiltmeter and Cobbmeter application is an equivalent Cobb measurement tool to the Oxford Cobbmeter. The advantages of smart phone are the accuracy of determining the most inclined vertebrae and accordingly more precise Cobb angle measurement. The new smart phones with these integrated applications may be really helpful to the spine surgeons, especially in hospitals where PACS or Oxford Cobbmeter is not available.
The aim of this study was to assess the performance of a new vacuum plasma sprayed (VPS) titanium-coated carbon/polyetheretherketone (PEEK) cage under first use clinical conditions. Forty-two patients who underwent a one or two segment transforaminal lumbar interbody fusion (TLIF) procedure with a new Ca/PEEK composite cage between 2012 and 2016 were retrospectively identified by an electronic patient chart review. Fusion rates (using X-ray), patient’s satisfaction, and complications were followed up for two years. A total of 90.4% of the patients were pain-free and satisfied after a follow up (FU) period of 29.1 ± 9 (range 24–39) months. A mean increase of 3° in segmental lordosis in the early period (p = 0.002) returned to preoperative levels at final follow-ups. According to the Bridwell classification, the mean 24-month G1 fusion rate was calculated as 93.6% and the G2 as 6.4%. No radiolucency around the cage (G3) or clear pseudarthrosis could be seen (G4). In conclusion, biological properties of the inert, hydrophobic surface, which is the main disadvantage of PEEK, can be improved with VPS titanium coating, so that the carbon/PEEK composite cage, which has great advantages in respect of biomechanical properties, can be used safely in TLIF surgery. High fusion rates, good clinical outcome, and low implant-related complication rates without the need to use rhBMP or additional iliac bone graft can be achieved.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.