Introduction:
Interlocking nailing for femoral shaft fractures is one of the most common surgeries by orthopedic traumatologists. With the advent of cephalon-medullary nailing, a center-center position of the head screw has become mandatory. With retroversion or reduced anteversion of neck, a center placement needs internal rotation of the nail. This makes distal locking problematic, as now making a perfect circle is difficult due to the physical constraints of C-arm rotation.
Objective:
To describe a novel technique to overcome the anatomic constraints and get a perfect circle for quick distal locking.
Material and Methods:
We used a novel technique in our routine femur nailing cases. Here, in cases with reduced anteversion of the neck, distal locking was tenuous due to difficulty in making a perfect circle. Thus, we have used a new technique called “Turning the table” where we externally rotate the table, which allows us to get a perfect circle for locking in almost a single exposure.
Results:
This is a useful technique in cases where getting a perfect circle is difficult due to anatomic constraints and variations and can help in getting a perfect circle with limited radiation exposure.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.