Rationale:Severe hypertriglyceridemia is the 3rd-leading cause of acute pancreatitis. Current treatment option for hypertriglyceridemia associated with acute pancreatitis is mainly supportive measures, including adequate fluid supply, pain management, and broad-spectrum antibiotics if necessary. Extracorporeal method by mean of plasmapheresis is effective in reducing serum level of triglyceride. It has been proposed to have therapeutic potential in limited small sample studies.Patient concerns:A retrospective review of therapeutic effect of double filtration plasmapheresis in treating hypertriglyceridemia associated with acute pancreatitis was conducted by enlisting 3 patients who meet the criteria for the present study.Diagnoses:Three patients met the criteria for hypertriglyceridemia (serum level >800 mg/dL) associated with acute pancreatitis (either with elevated serum level of lipase and/or amylase and/or with computed tomography evidence of acute pancreatitis).Interventions:Patients received double filtration plasmapheresis.Outcomes:We found that an effective reduction of triglyceride was achieved on an average of 84.7% as a result of a single session of plasmapheresis. All 3 of our patients survived, but needed extended hospitalization.Lessons:A substantial clinical trial is required to further assess the effectiveness of plasmapheresis in managing of acute pancreatitis in the setting of hypertriglyceridemia.
Due to the COVID-19 virus being highly transmittable, frequently cleaning and disinfecting facilities is common guidance in public places. However, the more often the environment is cleaned, the higher the risk of cleaning staff getting infected. Therefore, strong demand for sanitizing areas in automatic modes is undoubtedly expected. In this paper, an autonomous disinfection vehicle with an Ultraviolet-C (UVC) lamp is designed and implemented using an ultra-wideband (UWB) positioning sensor. The UVC dose for 90% inactivation of the reproductive ability of COVID-19 is 41.7 J/m2, which a 40 W UVC lamp can achieve within a 1.6 m distance for an exposure time of 30 s. With this UVC lamp, the disinfection vehicle can effectively sterilize in various scenarios. In addition, the high-accuracy UWB positioning system, with the time difference of arrival (TDOA) algorithm, is also studied for autonomous vehicle navigation in indoor environments. The number of UWB tags that use a synchronization protocol between UWB anchors can be unlimited. Moreover, this proposed Gradient Descent (GD), which uses Taylor method, is a high-efficient algorithm for finding the optimal position for real-time computation due to its low error and short calculating time. The generalized traversal path planning procedure, with the edge searching method, is presented to improve the efficiency of autonomous navigation. The average error of the practical navigation demonstrated in the meeting room is 0.10 m. The scalability of the designed system to different application scenarios is also discussed and experimentally demonstrated. Hence, the usefulness of the proposed UWB sensor applied to UVC disinfection vehicles to prevent COVID-19 infection is verified by employing it to sterilize indoor environments without human operation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.