Background Surgery is the main modality of cure for solid cancers and was prioritised to continue during COVID-19 outbreaks. This study aimed to identify immediate areas for system strengthening by comparing the delivery of elective cancer surgery during the COVID-19 pandemic in periods of lockdown versus light restriction. Methods This international, prospective, cohort study enrolled 20 006 adult (≥18 years) patients from 466 hospitals in 61 countries with 15 cancer types, who had a decision for curative surgery during the COVID-19 pandemic and were followed up until the point of surgery or cessation of follow-up (Aug 31, 2020). Average national Oxford COVID-19 Stringency Index scores were calculated to define the government response to COVID-19 for each patient for the period they awaited surgery, and classified into light restrictions (index <20), moderate lockdowns (20–60), and full lockdowns (>60). The primary outcome was the non-operation rate (defined as the proportion of patients who did not undergo planned surgery). Cox proportional-hazards regression models were used to explore the associations between lockdowns and non-operation. Intervals from diagnosis to surgery were compared across COVID-19 government response index groups. This study was registered at ClinicalTrials.gov , NCT04384926 . Findings Of eligible patients awaiting surgery, 2003 (10·0%) of 20 006 did not receive surgery after a median follow-up of 23 weeks (IQR 16–30), all of whom had a COVID-19-related reason given for non-operation. Light restrictions were associated with a 0·6% non-operation rate (26 of 4521), moderate lockdowns with a 5·5% rate (201 of 3646; adjusted hazard ratio [HR] 0·81, 95% CI 0·77–0·84; p<0·0001), and full lockdowns with a 15·0% rate (1775 of 11 827; HR 0·51, 0·50–0·53; p<0·0001). In sensitivity analyses, including adjustment for SARS-CoV-2 case notification rates, moderate lockdowns (HR 0·84, 95% CI 0·80–0·88; p<0·001), and full lockdowns (0·57, 0·54–0·60; p<0·001), remained independently associated with non-operation. Surgery beyond 12 weeks from diagnosis in patients without neoadjuvant therapy increased during lockdowns (374 [9·1%] of 4521 in light restrictions, 317 [10·4%] of 3646 in moderate lockdowns, 2001 [23·8%] of 11 827 in full lockdowns), although there were no differences in resectability rates observed with longer delays. Interpretation Cancer surgery systems worldwide were fragile to lockdowns, with one in seven patients who were in regions with full lockdowns not undergoing planned surgery and experiencing longer preoperative delays. Although short-term oncological outcomes were not compromised in those selected for surgery, delays and non-operations might lead to long-term reductions in survival. During current and future periods of societal restriction, the resilience of elective surgery systems requires strengthening, which might include...
In an effort to make laparoscopic suturing more efficient, the V-Loc advanced wound closure device (Covidien, Mansfield, MA) has been produced. This device is a self-anchoring barbed suture that obviates the need for knot tying. The goal of this initial feasibility study was to investigate the use of the barbed suture in gastrointestinal enterotomy closure. A randomized study of 12 pigs comparing enterotomy closure with barbed versus a nonbarbed suture of similar tensile strength was performed. To this end, 25 mm enterotomies were made in the stomach (1 control, 1 treatment), jejunum (2 controls, 2 treatments), and descending colon (1 control, 1 treatment). Animals were killed at 3, 7, and 14 days postoperatively (4 each group) and their gastrointestinal tracts harvested; 6 of the 8 enterotomies from each pig underwent burst strength testing. The remaining 2 were fixed in formalin and sent for histological examination. All 12 pigs survived until they were killed without any major complications. Enterotomy closure with barbed suture revealed adhesion scores, burst strength pressures, and histology scores that were similar to those for the control. Jejunal closures resulted in 6 failures at 7 days (3 control, 3 barbed) and 4 failures at 14 days (2 control, 2 barbed). The barbed suture significantly reduced suturing time in the stomach, jejunum, and colon. The V-Loc wound closure device appears to offer comparable gastrointestinal closure to 3-0 Maxon while being significantly faster. Further studies with V-Loc are required to assess its use in laparoscopic surgery.
After completion of TTT, there was a significant improvement in trauma resuscitation knowledge, based on results from a validated questionnaire. Trauma team performance was excellent when assessed with a novel trauma simulation assessment tool. Participants were very supportive of the course.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.