The detection of pathogens associated with gastrointestinal disease may be important in certain patient populations, such as immunocompromised hosts, the critically ill, or individuals with prolonged disease that is refractory to treatment. In this study, we evaluated two commercially available multiplex panels (the FilmArray gastrointestinal [GI] panel [BioFire Diagnostics, Salt Lake City, UT] and the Luminex xTag gastrointestinal pathogen panel [GPP] [Luminex Corporation, Toronto, Canada]) using Cary-Blair stool samples (n ؍ 500) submitted to our laboratory for routine GI testing (e.g., culture, antigen testing, microscopy, and individual real-time PCR). At the time of this study, the prototype (non-FDA-cleared) FilmArray GI panel targeted 23 pathogens (14 bacterial, 5 viral, and 4 parasitic), and testing of 200 l of Cary-Blair stool was recommended. In contrast, the Luminex GPP assay was FDA cleared for the detection of 11 pathogens (7 bacterial, 2 viral, and 2 parasitic), but had the capacity to identify 4 additional pathogens using a research-use-only protocol. Importantly, the Luminex assay was FDA cleared for 100 l raw stool; however, 100 l Cary-Blair stool was tested by the Luminex assay in this study. Among 230 prospectively collected samples, routine testing was positive for one or more GI pathogens in 19 (8.3%) samples, compared to 76 (33.0%) by the FilmArray and 69 (30.3%) by the Luminex assay. Clostridium difficile (12.6 to 13.9% prevalence) and norovirus genogroup I (GI)/GII (5.7 to 13.9% prevalence) were two of the pathogens most commonly detected by both assays among prospective samples. Sapovirus was also commonly detected (5.
Background Ehrlichiosis is a clinically important, emerging zoonosis. Only Ehrlichia chaffeensis and E. ewingii have been thought to cause ehrlichiosis in humans in the United States. Patients with suspected ehrlichiosis routinely undergo testing to ensure proper diagnosis and to ascertain the cause. Methods We used molecular methods, culturing, and serologic testing to diagnose and ascertain the cause of cases of ehrlichiosis. Results On testing, four cases of ehrlichiosis in Minnesota or Wisconsin were found not to be from E. chaffeensis or E. ewingii and instead to be caused by a newly discovered ehrlichia species. All patients had fever, malaise, headache, and lymphopenia; three had thrombocytopenia; and two had elevated liver-enzyme levels. All recovered after receiving doxycycline treatment. At least 17 of 697 Ixodes scapularis ticks collected in Minnesota or Wisconsin were positive for the same ehrlichia species on polymerase-chain-reaction testing. Genetic analyses revealed that this new ehrlichia species is closely related to E. muris. Conclusions We report a new ehrlichia species in Minnesota and Wisconsin and provide supportive clinical, epidemiologic, culture, DNA-sequence, and vector data. Physicians need to be aware of this newly discovered close relative of E. muris to ensure appropriate testing, treatment, and regional surveillance. (Funded by the National Institutes of Health and the Centers for Disease Control and Prevention.)
We evaluated Bruker Biotyper (version 2.0) matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry (MS) for the identification of 305 clinical isolates of staphylococci, streptococci, and related genera by comparing direct colony testing with preparatory extraction. Isolates were previously identified by use of phenotypic testing and/or 16S rRNA gene sequencing. Manufacturer-specified score cutoffs for genus-and species-level identification were used. After excluding 7 isolates not present in the Biotyper library, the Biotyper correctly identified 284 (95%) and 207 (69%) isolates to the genus and species levels, respectively, using extraction. By using direct colony testing, the Biotyper identified 168 (56%) and 60 (20%) isolates to the genus and species levels, respectively. Overall, more isolates were identified to the genus and species levels with preparatory extraction than with direct colony testing (P < 0.0001). The analysis was repeated after dividing the isolates into two subgroups, staphylococci, streptococci, and enterococci (n ؍ 217) and "related genera" (n ؍ 81). For the former subgroup, the extraction method resulted in the identification of 213 (98%) and 171 (79%) isolates to the genus and species levels, respectively, whereas the direct colony method identified 136 (63%) and 56 (26%) isolates to the genus and species levels, respectively. In contrast, for the subgroup of related genera, the extraction method identified 71 (88%) and 36 (44%) isolates to the genus and species levels, respectively, while the direct colony method identified 32 (40%) and 4 (5%) isolates to the genus and species levels, respectively. For both subgroups, preparatory extraction was superior to direct colony testing for the identification of isolates to the genus and species levels (P < 0.0001). Preparatory extraction is needed for the identification of a substantial proportion of Gram-positive cocci using the Biotyper method according to manufacturer-specified score cutoffs.
Hyperammonemia syndrome is a fatal complication affecting immunosuppressed patients. Frequently refractory to treatment, it is characterized by progressive elevations in serum ammonia of unknown etiology, ultimately leading to cerebral edema and death. In mammals, ammonia produced during amino acid metabolism is primarily cleared through the hepatic production of urea, which is eliminated in the kidney. Ureaplasma species, commensals of the urogenital tract, are Mollicutes dependent on urea hydrolysis to ammonia and carbon dioxide for energy production. We hypothesized that systemic infection with Ureaplasma species might pose a unique challenge to human ammonia metabolism by liberating free ammonia resulting in the hyperammonemia syndrome. We used polymerase chain reaction, specialized culture, and molecular resistance profiling to identify systemic Ureaplasma infection in lung transplant recipients with hyperammonemia syndrome, but did not detect it in any lung transplant recipients with normal ammonia concentrations. Administration of Ureaplasma-directed antimicrobials to patients with hyperammonemia syndrome resulted in biochemical and clinical resolution of the disorder. Relapse in one patient was accompanied by recurrent Ureaplasma bacteremia with antimicrobial resistance. Our results provide evidence supporting a causal relationship between Ureaplasma infection and hyperammonemia, suggesting a need to test for this organism and provide empiric antimicrobial treatment while awaiting microbiological confirmation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.