To develop a new technique that enables simultaneous quantification of whole‐brain T1, T2, T2∗, as well as susceptibility and synthesis of six contrast‐weighted images in a single 9.1‐minute scan.
Methods
The technique uses hybrid T2‐prepared inversion‐recovery pulse modules and multi‐echo gradient‐echo readouts to collect k‐space data with various T1, T2, and T2∗ weightings. The underlying image is represented as a six‐dimensional low‐rank tensor consisting of three spatial dimensions and three temporal dimensions corresponding to T1 recovery, T2 decay, and multi‐echo behaviors, respectively. Multiparametric maps were fitted from reconstructed image series. The proposed method was validated on phantoms and healthy volunteers, by comparing quantitative measurements against corresponding reference methods. The feasibility of generating six contrast‐weighted images was also examined.
Results
High quality, co‐registered T1, T2, and T2∗ susceptibility maps were generated that closely resembled the reference maps. Phantom measurements showed substantial consistency (R2 > 0.98) with the reference measurements. Despite the significant differences of T1 (p < .001), T2 (p = .002), and T2∗ (p = 0.008) between our method and the references for in vivo studies, excellent agreement was achieved with all intraclass correlation coefficients greater than 0.75. No significant difference was found for susceptibility (p = .900). The framework is also capable of synthesizing six contrast‐weighted images.
Conclusion
The MR Multitasking–based 3D brain mapping of T1, T2, T2∗, and susceptibility agrees well with the reference and is a promising technique for multicontrast and quantitative imaging.
PurposeTo evaluate the effect of resolution on iron content using quantitative susceptibility mapping (QSM); to verify the consistency of QSM across field strengths and manufacturers in evaluating the iron content of deep gray matter (DGM) of the human brain using subjects from multiple sites; and to establish a susceptibility baseline as a function of age for each DGM structure using both a global and regional iron analysis.MethodsData from 623 healthy adults, ranging from 20 to 90 years old, were collected across 3 sites using gradient echo imaging on one 1.5 Tesla and two 3.0 Tesla MR scanners. Eight subcortical gray matter nuclei were semi-automatically segmented using a full-width half maximum threshold-based analysis of the QSM data. Mean susceptibility, volume and total iron content with age correlations were evaluated for each measured structure for both the whole-region and RII (high iron content regions) analysis. For the purpose of studying the effect of resolution on QSM, a digitized model of the brain was applied.ResultsThe mean susceptibilities of the caudate nucleus (CN), globus pallidus (GP) and putamen (PUT) were not significantly affected by changing the slice thickness from 0.5 to 3 mm. But for small structures, the susceptibility was reduced by 10% for 2 mm thick slices. For global analysis, the mean susceptibility correlated positively with age for the CN, PUT, red nucleus (RN), substantia nigra (SN), and dentate nucleus (DN). There was a negative correlation with age in the thalamus (THA). The volumes of most nuclei were negatively correlated with age. Apart from the GP, THA, and pulvinar thalamus (PT), all the other structures showed an increasing total iron content despite the reductions in volume with age. For the RII regional high iron content analysis, mean susceptibility in most of the structures was moderately to strongly correlated with age. Similar to the global analysis, apart from the GP, THA, and PT, all structures showed an increasing total iron content.ConclusionA reasonable estimate for age-related iron behavior can be obtained from a large cross site, cross manufacturer set of data when high enough resolutions are used. These estimates can be used for correcting for age related iron changes when studying diseases like Parkinson’s disease, Alzheimer’s disease, and other iron related neurodegenerative diseases.
In this study, we have introduced an accurate retinal images registration method using affine moment invariants (AMI's) which are the shape descriptors. First, some closed-boundary regions are extracted in both reference and sensed images. Then, AMI's are computed for each of those regions. The centers of gravity of three pairs of regions which have the minimum of distances are selected as the control points. The region matching is performed by the distance measurements of AMI's. The evaluation of region matching is performed by comparing the angles of three triangles which are built on these three-point pairs in reference and sensed images. The parameters of affine transform can be computed using these three pairs of control points. The proposed algorithm is applied on the valid DRIVE database. In general (for the case, each sensed image is produced by rotating, scaling, and translating the reference image with different angles, scale factors, and translation factors), the success rate and accuracy is 95 and 96 %, respectively.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.