Purpose:To evaluate the early implementation of synthesized two-dimensional (s2D) mammography in a population screened entirely with s2D and digital breast tomosynthesis (DBT) (referred to as s2D/DBT) and compare recall rates and cancer detection rates to historic outcomes of digital mammography combined with DBT (referred to as digital mammography/DBT) screening.
Materials and Methods:This was an institutional review board-approved and HIPAA-compliant retrospective interpretation of prospectively acquired data with waiver of informed consent. Compared were recall rates, biopsy rates, cancer detection rates, and radiation dose for 15 571 women screened with digital mammography/DBT from October 1, 2011, to February 28, 2013, and 5366 women screened with s2D/ DBT from January 7, 2015, to June 30, 2015. Two-sample z tests of equal proportions were used to determine statistical significance.
Results:Recall rate for s2D/DBT versus digital mammography/ DBT was 7.1% versus 8.8%, respectively (P , .001). Biopsy rate for s2D/DBT versus digital mammography/ DBT decreased (1.3% vs 2.0%, respectively; P = .001).There was no significant difference in cancer detection rate for s2D/DBT versus digital mammography/DBT (5.03 of 1000 vs 5.45 of 1000, respectively; P = .72). The average glandular dose was 39% lower in s2D/DBT versus digital mammography/DBT (4.88 mGy vs 7.97 mGy, respectively; P , .001).
Conclusion:Screening with s2D/DBT in a large urban practice resulted in similar outcomes compared with digital mammography/DBT imaging. Screening with s2D/DBT allowed for the benefits of DBT with a decrease in radiation dose compared with digital mammography/DBT.q RSNA, 2016
Despite subjective differences in the appearance of s2D and digital mammograms, early outcomes of screening using s2D mammography and DBT are not inferior to those achieved with digital mammography and DBT. Understanding these variations may aid in implementing this technique and improving patient outcomes.
PURPOSE Although mammography is the standard of care for breast cancer screening, dense breast tissue decreases mammographic sensitivity. We report the prevalent cancer detection rate (CDR) from the first clinical implementation of abbreviated breast magnetic resonance imaging (AB-MR) as a supplemental screening test in women with dense breasts. METHODS The study was approved by the institutional review board and is Health Insurance Portability and Accountability Act complaint. This retrospective review includes women who were imaged between January 1, 2016 and February 28, 2019. On a 1.5 Tesla magnet, the imaging protocol consisted of three sequences: Short-TI Inversion Recovery (STIR), precontrast, and postcontrast. A subtraction sequence and a maximum intensity projection were generated. We report the patient-level CDR and the positive predictive value of AB-MR examinations after negative/benign digital breast tomosynthesis (DBT). RESULTS Out of 511 prevalent rounds of AB-MR examinations, 36 women were excluded. The remaining 475 asymptomatic women with dense breasts had negative/benign DBT examinations before the AB-MR. There were 420 of 475 (88.4%) benign/negative examinations, 13 of 475 (2.7%) follow-up recommendations, and 42 biopsy recommendations. Thirty-nine biopsies were completed, resulting in 12/39 (30.8%) malignancies in 12 women: seven invasive carcinomas and five ductal carcinoma in situ. One additional patient was diagnosed with invasive ductal carcinoma at the time of 6-month follow-up. The CDR was 27.4 per 1,000 (13 of 475; 95% CI, 16.1 to 46.3). The size of invasive carcinomas ranged from 0.6-1.0 cm (mean, 0.5 cm). Of the seven women who underwent surgical evaluation of the axilla, zero of seven patients had positive nodes. There were no interval cancers at 1-year follow-up. CONCLUSION Preliminary results from clinical implementation of screening AB-MR resulted in a CDR of 27.4/1,000 at the patient level after DBT in women with dense breasts. Additional evaluation is warranted.
The majority of practices responding to the survey screening with DBT have SM capability; however, SM usage with DM in DBT screening is varied as is radiologist satisfaction.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.