Halcyon™ is a single‐energy (6 MV‐FFF), bore‐enclosed linear accelerator. Patient setup is performed by first aligning to external lasers mounted to the front of the bore, and then loading to isocenter through pre‐defined couch shifts. There is no light field, optical distance indicator or front pointer mechanism, so positioning is verified through MV imaging with kV imaging scheduled to become available in the future. TG‐51 reference dosimetry was successfully performed for Halcyon™ in this imaging‐based setup paradigm. The beam quality conversion factor, k Q, was determined by measuring %dd(10)x three ways: (a) using a Farmer chamber with lead filtering, (b) using a Farmer chamber without lead filtering, and (c) using a PinPoint chamber without lead filtering. Values of k Q were determined to be 0.995, 0.996, and 0.996 by each measurement technique, respectively. Halcyon™'s 6 MV‐FFF beam was found to be broader than other FFF beams produced by Varian accelerators, and profile measurements at d max showed the beam to vary less than 0.5% over the dimensions of our Farmer chamber's active volume. Reference dosimetry can be performed for the Halcyon™ accelerator simply, without specialized equipment or lead filtering with minimal dosimetric impact. This simplicity will prove advantageous in clinics with limited resources or physics support.
Acuros XB is shown to perform as well as Monte Carlo methods and better than existing clinical algorithms for dose calculations involving high-density volumes.
TrueBeam electron phase-spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase-space off-axis and in the outputs for the 6 MeV phase-space.
Dosimetric comparisons of radiation fields produced by Varian's newest linear accelerator, the TrueBeam, with those produced by older Varian accelerators are of interest from both practical and research standpoints. While photon fields have been compared in the literature, similar comparisons of electron fields have not yet been reported. In this work, electron fields produced by the TrueBeam are compared with those produced by Varian's Clinac 21EX accelerator. Diode measurements were taken of fields shaped with electron applicators and delivered at 100 cm SSD, as well as those shaped with photon MLCs without applicators and delivered at 70 cm SSD for field sizes ranging from 5×5 to 25×25 cm2 at energies between 6 and 20 MeV. Additionally, EBT2 and EBT3 radio‐chromic film measurements were taken of an MLC‐shaped aperture with closed leaf pairs delivered at 70 cm SSD using 6 and 20 MeV electrons. The 6 MeV fields produced by the TrueBeam and Clinac 21EX were found to be almost indistinguishable. At higher energies, TrueBeam fields shaped by electron applicators were generally flatter and had less photon contamination compared to the Clinac 21EX. Differences in PDDs and profiles fell within 3% and 3 mm for the majority of measurements. The most notable differences for open fields occurred in the profile shoulders for the largest applicator field sizes. In these cases, the TrueBeam and Clinac 21EX data differed by as much as 8%. Our data indicate that an accurate electron beam model of the Clinac 21EX could be used as a starting point to simulate electron fields that are dosimetrically equivalent to those produced by the TrueBeam. Given that the Clinac 21EX shares head geometry with Varian's iX, Trilogy, and Novalis TX accelerators, our findings should also be applicable to these machines.PACS number: 87.56.bd
To accurately simulate therapeutic electron beams using Monte Carlo methods, backscatter from jaws into the monitor chamber must be accounted for via the backscatter factor, S . Measured and simulated values of S for the TrueBeam are investigated. Two approaches for measuring S are presented. Both require service mode operation with the dose and pulse forming networking servos turned off in order to assess changes in dose rate with field size. The first approach samples an instantaneous dose rate, while the second approach times the delivery of a fixed number of monitor units to assess dose rate. Dose rates were measured for 6, 12 and 20 MeV electrons for jaw- or MLC-shaped apertures between [Formula: see text] and [Formula: see text] cm. The measurement techniques resulted in values of S that agreed within 0.21% for square and asymmetric fields collimated by the jaws. Measured values of S were used to calculate the forward dose component in a virtual monitor chamber using BEAMnrc. Based on this forward component, simulated values of S were calculated and compared to measurement and Varian's VirtuaLinac simulations. BEAMnrc results for jaw-shaped fields agreed with measurements and with VirtuaLinac simulations within 0.2%. For MLC-shaped fields, the respective measurement techniques differed by as much as 0.41% and BEAMnrc results differed with measurement by as much as 0.4%, however, all measured and simulated values agreed within experimental uncertainty. Measurement sensitivity was not sufficient to capture the small backscatter effect due to the MLC, and Monte Carlo predicted backscatter from the MLC to be no more than 0.3%. Backscatter from the jaws changed the electron dose rate by up to 2.6%. This reinforces the importance of including a backscatter factor in simulations of electron fields shaped with secondary collimating jaws, but presents the option of ignoring it when jaws are retracted and collimation is done with the MLC.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.