Faithfully recapitulating human physiology "in a dish" from a renewable source remains a holy grail for medicine and pharma. Many procedures have been described that, to a limited extent, exhibit human tissue-specific function in vitro. In particular, incomplete cellular differentiation and/or the loss of cell phenotype postdifferentiation play a major part in this void. We have developed an interdisciplinary approach to address this problem, using skill sets in cell biology, materials chemistry, and pharmacology. Pluripotent stem cells were differentiated to hepatocytes before being replated onto a synthetic surface. Our approach yielded metabolically active hepatocyte populations that displayed stable function for more than 2 weeks in vitro. Although metabolic activity was an important indication of cell utility, the accurate prediction of cellular toxicity in response to specific pharmacological compounds represented our goal. Therefore, detailed analysis of hepatocellular toxicity was performed in response to a custom-built and well-defined compound set and compared with primary human hepatocytes. Importantly, stem cell-derived hepatocytes displayed equivalence to primary human material. Moreover, we demonstrated that our approach was capable of modeling metabolic differences observed in the population. In conclusion, we report that pluripotent stem cell-derived hepatocytes will model toxicity predictably and in a manner comparable to current gold standard assays, representing a major advance in the field. STEM CELLS TRANSLATIONAL MEDICINE 2013;2:505-509
Maintaining stable differentiated somatic cell function in culture is essential to a range of biological endeavors. However, current technologies, employing, for example, primary hepatic cell culture (essential to the development of a bio-artificial liver and improved drug and toxicology testing), are limited by supply, expense, and functional instability even on biological cell culture substrata. As such, novel biologically active substrates manufacturable to GMP standards have the potential to improve cell culture-based assay applications. Currently hepatic endoderm (HE) generated from pluripotent stem cells is a genotypically diverse, cheap, and stable source of "hepatocytes"; however, HE routine applications are limited due to phenotypic instability in culture. Therefore a manufacturable subcellular matrix capable of supporting long-term differentiated cell function would represent a step forward in developing scalable and phenotypically stable hESC-derived hepatocytes. Adopting an unbiased approach we screened polymer microarrays and identified a polyurethane matrix which promoted HE viability, hepatocellular gene expression, drug-inducible metabolism, and function. Moreover, the polyurethane supported, when coated on a clinically approved bio-artificial liver matrix, long-term hepatocyte function and growth. In conclusion, our data suggest that an unbiased screening approach can identify cell culture substrate(s) that enhance the phenotypic stability of primary and stem cell-derived cell resources.
We have developed a single probe method for detecting microRNA from human serum using single molecule arrays, with sequence specificity down to a single base, and without the use of amplification by polymerases. An abasic peptide nucleic acid (PNA) probe—containing a reactive amine instead of a nucleotide at a specific position in the sequence—for detecting a microRNA was conjugated to superparamagnetic beads. These beads were incubated with a sample containing microRNA, a biotinylated reactive nucleobase—containing an aldehyde group—that was complementary to the missing base in the probe sequence, and a reducing agent. When a target molecule with an exact match in sequence hybridized to the capture probe, the reactive nucleobase was covalently attached to the backbone of the probe by a dynamic covalent chemical reaction. Single molecules of the biotin-labeled probe were then labeled with streptavidin-β-galactosidase (SβG), the beads were resuspended in a fluorogenic enzyme substrate, loaded into an array of femtoliter wells, and sealed with oil. The array was imaged fluorescently to determine which beads were associated with single enzymes, and the average number of enzymes per bead was determined. The assay had a limit of detection of 500 fM, approximately 500 times more sensitive than a corresponding analog bead-based assay, with target specificity down to a single base mis-match. This assay was used to measure microRNA-122 (miR-122)—an established biomarker of liver toxicity—extracted from the serum of patients who had acute liver injury due to acetaminophen, and control healthy patients. All patients with liver injury had higher levels of miR-122 in their serum compared to controls, and the concentrations measured correlated well with those determined using RT-qPCR. This approach allows rapid quantification of circulating microRNA with single-based specificity and a limit of quantification suitable for clinical use.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.