Background Over the past ten years, regenerative medicine has focused on the regeneration and the reconstruction of damaged, diseased, or lost tissues and organs. Skin, being the largest organ in the human body, had attained a good attraction in this field. Delayed wound healing is one of the most challenging clinical medicine complications. This study aimed to evaluate the collagen chitosan scaffold’s effect alone, or enriched with either bone marrow-derived mesenchymal stem cells (BM-MSCs) or their secreted extracellular vesicles (EVs) on the duration and quality of skin wound healing. Methods A full-thickness skin wound was induced on the back of 32 adult male Sprague-Dawley rats. The wounds were either covered with collagen chitosan scaffolds alone, scaffolds enriched with stem cells, or extracellular vesicles. Unprotected wounds were used as control. Healing duration, collagen deposition and alignment, CD 68+ macrophage count, and functional tensile strength of healed skin were assessed (α = 0.05, n = 8). Results The rate of skin healing was significantly accelerated in all treated groups compared to the control. Immuno-histochemical assessment of CD68+ macrophages showed enhanced macrophages count, in addition to higher collagen deposition and better collagen alignment in EVs and BM-MSCs treated groups compared to the control group. Higher tensile strength values reflected the better collagen deposition and alignment for these groups. EVs showed higher amounts of collagen deposition and better alignment compared to MSCs treated group. Conclusion The collagen chitosan scaffolds enriched with MSCs or their EVs improved wound healing and improved the quantity and remodeling of collagen with a better assignment to EVs.
Objectives: This study aimed to investigate the effects of ECIG smoking on color stability of simulated veneers made from lithium disilicate glass ceramics.Materials and methods: 24 specimens of lithium disilicate glass ceramic veneers were exposed to aerosols which are flavored and non-flavored with nicotine content (0, 6 and 12 mg). Six specimens were prepared for each group IPS E.Max press high translucent ceramic discs. Vacuum Induction Device was used to simulate smoking in vivo. Color measurement was performed on the specimens before and after exposure to ECIG aerosol using a calibrated spectrophotometer.Results: According to Two Way ANOVA, both flavor and nicotine contents have significant effect on color change (P <0.0001). Regarding specimens exposed to e-liquid, flavorless 0 mg. nicotine group showed the lowest value 1.044 (±0.044), while flavored 12 mg. nicotine group showed the highest values 2.369 (±0.034). As for specimens which exposed to e-liquid, flavorless group lowest value 1.197 was found, while flavored group showed the highest values 1.868. Regarding specimens which exposed to e-liquid, group which exposed to 0 mg nicotine showed the lowest value 1.268 (±0.233), while group exposed to 12 mg nicotine showed the highest values 1.868 (±0.524). Conclusion:Study showed that exposure to flavored and non-flavored ECIG aerosol of different nicotine concentrations has a significant effect on the color of lithium disilicate glass ceramic veneers. Higher concentrations of flavored nicotine had visually perceptible color changes and were deemed clinically unacceptable.
Background Splinted multiunit cement-retained restorations with screw access channels over engaging abutments are viable implant prosthetic options. However, information regarding the maximum degree of divergence between multiple implants is lacking. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of splinted restorations with engaging preparable abutments or titanium base abutments. Methods Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0 to 20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0–10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman’s rank correlation coefficient. Results The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman’s rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. Conclusions Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.
Background The use of engaging abutments with splinted cement retained restorations with screw access channels is essential to maintain abutment orientation. The purpose of this in vitro study was to determine the maximum degree of divergence between 2 adjacent implants with conical connections that allows insertion and removal of a splinted screw-retained restoration with engaging preparable abutments or titanium base abutments. Methods Two implants were aligned in a stone base, one straight and the other at an angle ranging from 0–20 degrees. The implants represented an implant system that had an internal conical connection and a hexed abutment engaging the base of the connection. Two straight preparable engaging cement retained abutments were screwed onto the implants and splinted together using acrylic resin. A total of 11 angles were tested, with 7 specimens for every angle. Evaluation of dislodging force was performed by pulling out the splinted abutments after unscrewing them. This was performed subjectively by 3 blinded investigators who applied a tactile pulling force. A scale of 0–10 was used to estimate the pulling force. Objectively the dislodging force was measured in Newtons using a universal testing machine. A statistical correlation was made between the subjective and objective dislodging force values using Spearman’s rank correlation coefficient. Results The mean subjective values increased gradually from 0 to 16 degrees. A sudden rise was noticed at 18 degrees (9.71 ± 0.23) and, at 20 degrees, the investigators were not able to remove the splinted abutments from the implants. The mean objective dislodgement force values increased gradually from 0 to16 degrees and abruptly from 16 degrees (13.57 ± 0.45 N) to 18 degrees (25.40 ± 0.66 N) and 20 degrees (35.22 ± 0.64). The correlation between the subjective and the objective evaluations assessed using the Spearman’s rank correlation coefficient was 0.98 indicating a statistically significant correlation (P < .001). As the objective dislodging force increased, the subjective dislodgement difficulty increased. Conclusions Splinting cement retained restorations with screw access channels on engaging abutments is possible when multiple implants with conical connections having an internal flare angle of 8 degrees are used, with implant divergence of up to 16 degrees.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.