OBJECTIVES
The goal of this study was to investigate the association between the localization of the distal anastomosis (zone 2/3), the stent graft length (100–160 mm), the position of the distal end of the hybrid prosthesis and the need for secondary aortic intervention (SAI) in acute and chronic thoracic aortic disease after the frozen elephant trunk procedure.
METHODS
From 2009 through 2020, a total of 232 patients (137 men; mean age, 61.7 ± 13.8 years) were treated with the frozen elephant trunk procedure. The main indications were acute aortic dissection type A (n = 106, 46%), chronic aortic dissection type A (n = 52, 22%) and degenerative thoracic aortic aneurysm (n = 74, 32%).
RESULTS
The rate of SAI was significantly higher when we performed a distal anastomosis in zone 2 rather than in zone 3, whereas the rate of SAI was less frequent if the distal positioning of the hybrid prosthesis was below TH 4–5. Combining the zone 2 concept and the short stent graft length (100 mm) was associated with a significantly higher rate of SAIs. Patients with a distal anastomosis in zone 2 were significantly less likely to have a recurrent laryngeal nerve injury (P < 0.001). However, no association between a specific arch zone of a distal anastomosis and the occurrence of spinal cord injury was observed.
CONCLUSIONS
Rates of SAIs are highest in patients who were treated with a distal anastomosis in zone 2 and a short stent graft (100 mm) with the distal end of the hybrid prosthesis at vertebral level TH 2–3.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.