Today, continuous-flow left ventricular assist devices (cf-LVADs) are implanted more often in patients with end-stage heart failure. Because of greater durability they can be implanted for an extended period of time. As a result of increased numbers of patients on cf-LVAD support, healthcare professionals should be aware of the potential complications inherent to this therapy. Both bleeding and thrombosis may occur, and also complications related either to the device itself or to the ensuing altered haemodynamics, valvular pathology, and rhythm disturbances such as ventricular tachycardias and fibrillation. Accurate clinical evaluation, together with an electrocardiogram and, if necessary, combined with an echocardiogram, is obligatory in these situations. This review summarizes common complications complemented by a few clinical cases.--
dInfections with cardiotrophic viruses and immune-mediated responses against the heart have been suggested to play a dominant role in the pathogenesis of idiopathic dilated cardiomyopathy (DCM). Furthermore, immune-mediated inflammatory diseases (IMIDs) may result in DCM. It has not previously been assessed whether DCM patients with and without an IMID have different prevalences and quantities of cardiotrophic viruses in the heart. Therefore, we compared the profiles of cardiotrophic viruses in heart tissue of DCM patients with and without an IMID. Serum and myocardial tissue samples were obtained from 159 consecutive patients with DCM and 20 controls. Patients were subdivided into three groups, the first two based on the presence (n ؍ 34) or absence (n ؍ 125) of an IMID and the third being a control group. The parvovirus B19 virus genome was detected in equal quantities in the non-IMID DCM patients (100/125) and the control group (15/20) but in lower quantities in the IMID patients (21/34, P ؍ 0.02). Both the non-IMID and IMID DCM patients demonstrated increased myocardial inflammation compared to controls: 12.5 ؎ 1.8 and 14.0 ؎ 3.2 CD45-positive inflammatory cells, respectively, versus 5.1 ؎ 0.7 for the controls (P < 0.05 for both). Importantly, significantly higher parvovirus B19 copy numbers could be amplified in non-IMID than in IMID patients (561 ؎ 97 versus 191 ؎ 92 copies/g DNA, P < 0.001) and control subjects (103 ؎ 47 copies/g DNA, P < 0.001). The present study shows decreased parvovirus B19 prevalence and copy numbers in hearts of DCM patients with an IMID compared to those without an IMID. These findings may suggest that DCM patients with an IMID have a different pathophysiologic mechanism from that which is present in the virus-induced form of DCM.
Background The prevalence of heart failure (HF) is increasing substantially and, despite improvements in medical therapy, HF still carries a poor prognosis. Mechanical circulatory support (MCS) by a continuousflow left ventricular assist device (cf-LVAD) improves survival and quality of life in selected patients. This holds especially for the short-term outcome, but experience regarding long-term outcome is growing as the waiting time for heart transplantation is increasing due to the shortage of donor hearts. Here we present our results from the University Medical Centre Utrecht. Methods Data of all patients with a cf-LVAD implant between March 2006 and January 2018 were collected. The primary outcome was survival. Secondary outcomes included adverse events defined according to the Interagency Registry for Mechanically Assisted Cir-Electronic supplementary material The online version of this article (
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.