Current detection methods for contamination of aflatoxin and fumonisin used in the corn industry are based on bulk level. However, literature demonstrates that contamination of these mycotoxins is highly skewed and bulk samples do not always represent accurately the overall contamination in a batch of corn. Single kernel analysis can provide an insightful level of analysis of the contamination of aflatoxin and fumonisin, as well as suggest a possible remediation to the skewness present in bulk detection. Current literature describes analytical methods capable of detecting aflatoxin and fumonisin at a single kernel level, such as liquid chromatography, fluorescence imaging, and reflectance imaging. These methods could provide tools to classify mycotoxin contaminated kernels and study potential co-occurrence of aflatoxin and fumonisin. Analysis at a single kernel level could provide a solution to the skewness present in mycotoxin contamination detection and offer improved remediation methods through sorting that could impact food security and management of food waste.
While complex sample pooling strategies have been developed for large-scale experiments with robotic liquid handling, many medium-scale experiments like mycotoxin screening by Enzyme-Linked Immunosorbent Assay (ELISA) are still conducted manually in 48-and 96well plates. At this scale, the opportunity to save on reagent costs is offset by the increased costs of labor, materials, and risk-of-error caused by increasingly complex pooling strategies. This paper compares one-dimensional (1D), two-dimensional (2D), and Shifted Transversal Design (STD) pooling to study whether pooling affects assay accuracy and experimental cost and to provide guidance for when a human experimentalist might benefit from pooling. We approximated mycotoxin contamination in single corn kernels by fitting statistical distributions to experimental data (432 kernels for aflatoxin and 528 kernels for fumonisin) and used experimentally-validated Monte-Carlo simulation (10,000 iterations) to evaluate assay sensitivity, specificity, reagent cost, and pipetting cost. Based on the validated simulation results, assay sensitivity remains 100% for all four pooling strategies while specificity decreases as prevalence level rises. Reagent cost could be reduced by 70% and 80% in 48-and 96-well plates, with 1D and STD pooling being most reagent-saving respectively. Such a reagent-saving effect is only valid when prevalence level is < 21% for 48-well plates and < 13%-21% for 96-well plates. Pipetting cost will rise by 1.3-3.3 fold for 48-well plates and 1.2-4.3 fold for 96-well plates, with 1D pooling by row requiring the least pipetting. Thus, it is advisable to employ pooling when the expected prevalence level is below 21% and when the likely savings of up to 80% on reagent cost outweighs the increased materials and labor costs of up to 4 fold increases in pipetting.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.