An internal-target technique was used to make the first measurements of the tensor analyzing power 7^20 of electron-deuteron elastic scattering in the four-momentum-transfer range of 2-3 fm _l . Polarized deuterium atoms were confined within a storage cell in the VEPP-3 electron storage ring in Novosibirsk to achieve a total target thickness of 3x 10 12 cm ~2, 15 times greater than was previously possible with an atomic-beam target alone. The results for T20 are in agreement with reasonable models of the deuteron wave function.
The construction and use of a dual radiator Ring Imaging Cherenkov (RICH) detector is described. This instrument was developed for the HERMES experiment at DESY which emphasises measurements of semi-inclusive deep-inelastic scattering. It provides particle identification for pions, kaons, and protons in the momentum range from 2 to 15 GeV, which is essential to these studies. The instrument uses two radiators, C4F10, a heavy fluorocarbon gas, and a wall of silica aerogel tiles. The use of aerogel in a RICH detector has only recently become possible with the development of clear, large, homogeneous and hydrophobic aerogel. A lightweight mirror was constructed using a newly perfected technique to make resin-coated carbon-fiber surfaces of optical quality. The photon detector consists of 1934 photomultiplier tubes (PMT) for each detector half, held in a soft steel matrix to provide shielding against the residual field of the main spectrometer magnet. (C) 2002 Elsevier Science B.V. All rights reserved
In this work, we investigate the high temperature performance of mid-wavelength infrared InAsSb-AlAsSb nBn detectors with cut-off wavelengths near 4.5 μm. The quantum efficiency of these devices is 35% without antireflection coatings and does not change with temperature in the 77–325 K temperature range, indicating potential for room temperature operation. The current generation of nBn detectors shows an increase of operational bias with temperature, which is attributed to a shift in the Fermi energy level in the absorber. Analysis of the device performance shows that operational bias and quantum efficiency of these detectors can be further improved. The device dark current stays diffusion limited in the 150 K–325 K temperature range and becomes dominated by generation-recombination processes at lower temperatures. Detector detectivities are D*(λ) = 1 × 109 (cm Hz0.5/W) at T = 300 K and D*(λ) = 5 × 109 (cm Hz0.5/W) at T = 250 K, which is easily achievable with a one stage TE cooler.
SummaryTemporomandibular joint ankylosis is defined as bony or fibrous adhesion of the anatomic joint components accompanied by a limitation in opening the mouth, causing difficulties with mastication, speaking and oral hygiene as well as inadvertently influencing mandibular growth. Surgical treatment procedures include arthroplasty of the joint cavity with or without a reconstruction and a coronoidectomy, an autogenous costochondral rib graft, distraction osteogenesis and intensive mouth-opening exercise, corrective orthognathic surgery or alloplastic joint prostheses. The authors of this study would like to provide the reader with an evidence-based review of the literature in order to determine the most efficient way to manage TMJ ankylosis and re-ankylosis. The authors have concluded that in order to achieve a satisfactory and durable effective treatment, an individualized approach is necessary in each case.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.