The development of operative laparoscopic surgery is linked to advances in ancillary surgical instrumentation. Ultrasonic energy devices avoid the use of electricity and provide effective control of small- to medium-sized vessels. Bipolar computer-controlled electrosurgical technology eliminates the disadvantages of electrical energy, and a mechanical blade adds a cutting action. This instrument can provide effective hemostasis of large vessels up to 7 mm. Such devices significantly increase the cost of laparoscopic procedures, however, and the amount of evidence-based information on this topic is surprisingly scarce. This study compared the effectiveness of three different energy sources on the laparoscopic performance of a left colectomy. The trial included 38 nonselected patients with a disease of the colon requiring an elective segmental left-sided colon resection. Patients were preoperatively randomized into three groups. Group I had electrosurgery; vascular dissection was performed entirely with an electrosurgery generator, and vessels were controlled with clips. Group II underwent computer-controlled bipolar electrosurgery; vascular and mesocolon section was completed by using the 10-mm Ligasure device alone. In group III, 5-mm ultrasonic shears (Harmonic Scalpel) were used for bowel dissection, vascular pedicle dissection, and mesocolon transection. The mesenteric vessel pedicle was controlled with an endostapler. Demographics (age, sex, body mass index, comorbidity, previous surgery and diagnoses requiring surgery) were recorded, as were surgical details (operative time, conversion, blood loss), additional disposable instruments (number of trocars, EndoGIA charges, and clip appliers), and clinical outcome. Intraoperative economic costs were also evaluated. End points of the trial were operative time and intraoperative blood loss, and an intention-to-treat principle was followed. The three groups were well matched for demographic and pathologic features. Surgical time was significantly longer in patients operated on with conventional electrosurgery vs the Harmonic Scalpel or computed-based bipolar energy devices. This finding correlated with a significant reduction in intraoperative blood loss. Conversion to other endoscopic techniques was more frequent in Group I; however, conversion to open surgery was similar in all three groups. No intraoperative accident related to the use of the specific device was observed in any group. Immediate outcome was similar in the three groups, without differences in morbidity, mortality, or hospital stay. Analysis of operative costs showed no significant differences between the three groups. High-energy power sources specifically adapted for endoscopic surgery reduce operative time and blood loss and may be considered cost-effective when left colectomy is used as a model.
Renal biopsies carried out by ultrasonography using an 18-G needle provide adequate histological analysis, showing a lower amount of glomeruli but with similar clinical quality as a 16-G needle. Furthermore, it is associated with a lower risk of procedure-related complications.
Since 1990, we have performed splenic autotransplantation in more than 100 patients to treat splenic trauma, portal hypertension, myeloid metaplasia due to myelofibrosis, chronic lymphocytic leukemia, and Gaucher disease. The aim of this present study was to present splenic autotransplantation performed by laparoscopic means. A 33-year-old woman with severe splenic pain due to ischemia caused by multiple focal thromboses of splenic arterial branches was successfully treated by laparoscopic splenectomy and splenic tissue autotransplantation. The spleen was removed and cut in 20 fragments that were sutured to the greater omentum. This procedure was safely conducted with minor bleeding and no technical difficulties or complications. The postoperative follow-up of 12 months has been uneventful; the patient's pain disappeared on the first postoperative day. Hematologic, immunologic, tomographic, and scintigraphic examinations confirmed the functions of the splenic autotransplants. It is feasible and safe to perform splenic autotransplants by laparoscopic means.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.