The looming potential of deformable alignment tools to play an integral role in adaptive radiotherapy suggests a need for objective assessment of these complex algorithms. Previous studies in this area are based on the ability of alignment to reproduce analytically generated deformations applied to sample image data, or use of contours or bifurcations as ground truth for evaluation of alignment accuracy. In this study, a deformable phantom was embedded with 48 small plastic markers, placed in regions varying from high contrast to roughly uniform regional intensity, and small to large regional discontinuities in movement. CT volumes of this phantom were acquired at different deformation states. After manual localization of marker coordinates, images were edited to remove the markers. The resulting image volumes were sent to five collaborating institutions, each of which has developed previously published deformable alignment tools routinely in use. Alignments were done, and applied to the list of reference coordinates at the inhale state. The transformed coordinates were compared to the actual marker locations at exhale. A total of eight alignment techniques were tested from the six institutions. All algorithms performed generally well, as compared to previous publications. Average errors in predicted location ranged from 1.5 to 3.9 mm, depending on technique. No algorithm was uniformly accurate across all regions of the phantom, with maximum errors ranging from 5.1 to 15.4 mm. Larger errors were seen in regions near significant shape changes, as well as areas with uniform contrast but large local motion discontinuity. Although reasonable accuracy was achieved overall, the variation of error in different regions suggests caution in globally accepting the results from deformable alignment.
The incorporation of daily images into the radiotherapy process leads to adaptive radiation therapy (ART), in which the treatment is evaluated periodically and the plan is adaptively modified for the remaining course of radiotherapy. Deformable registration between the planning image and the daily images is a key component of ART. In this paper, we report our researches on deformable registration between the planning kVCT and the daily MVCT image sets. The method is based on a fast intensity-based free-form deformable registration technique. Considering the noise and contrast resolution differences between the kVCT and the MVCT, an 'edge-preserving smoothing' is applied to the MVCT image prior to the deformable registration process. We retrospectively studied daily MVCT images from commercial TomoTherapy machines from different clinical centers. The data set includes five head-neck cases, one pelvis case, two lung cases and one prostate case. Each case has one kVCT image and 20-40 MVCT images. We registered the MVCT images with their corresponding kVCT image. The similarity measures and visual inspections of contour matches by physicians validated this technique. The applications of deformable registration in ART, including 'deformable dose accumulation', 'automatic re-contouring' and 'tumour growth/regression evaluation' throughout the course of radiotherapy are also studied.
Purpose Automatic segmentation of organs‐at‐risk (OARs) is a key step in radiation treatment planning to reduce human efforts and bias. Deep convolutional neural networks (DCNN) have shown great success in many medical image segmentation applications but there are still challenges in dealing with large 3D images for optimal results. The purpose of this study is to develop a novel DCNN method for thoracic OARs segmentation using cropped 3D images. Methods To segment the five organs (left and right lungs, heart, esophagus and spinal cord) from the thoracic CT scans, preprocessing to unify the voxel spacing and intensity was first performed, a 3D U‐Net was then trained on resampled thoracic images to localize each organ, then the original images were cropped to only contain one organ and served as the input to each individual organ segmentation network. The segmentation maps were then merged to get the final results. The network structures were optimized for each step, as well as the training and testing strategies. A novel testing augmentation with multiple iterations of image cropping was used. The networks were trained on 36 thoracic CT scans with expert annotations provided by the organizers of the 2017 AAPM Thoracic Auto‐segmentation Challenge and tested on the challenge testing dataset as well as a private dataset. Results The proposed method earned second place in the live phase of the challenge and first place in the subsequent ongoing phase using a newly developed testing augmentation approach. It showed superior‐than‐human performance on average in terms of Dice scores (spinal cord: 0.893 ± 0.044, right lung: 0.972 ± 0.021, left lung: 0.979 ± 0.008, heart: 0.925 ± 0.015, esophagus: 0.726 ± 0.094), mean surface distance (spinal cord: 0.662 ± 0.248 mm, right lung: 0.933 ± 0.574 mm, left lung: 0.586 ± 0.285 mm, heart: 2.297 ± 0.492 mm, esophagus: 2.341 ± 2.380 mm) and 95% Hausdorff distance (spinal cord: 1.893 ± 0.627 mm, right lung: 3.958 ± 2.845 mm, left lung: 2.103 ± 0.938 mm, heart: 6.570 ± 1.501 mm, esophagus: 8.714 ± 10.588 mm). It also achieved good performance in the private dataset and reduced the editing time to 7.5 min per patient following automatic segmentation. Conclusions The proposed DCNN method demonstrated good performance in automatic OAR segmentation from thoracic CT scans. It has the potential for eventual clinical adoption of deep learning in radiation treatment planning due to improved accuracy and reduced cost for OAR segmentation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.