BACKGROUND AND PURPOSE:Previous studies showed conflicting results concerning the value of CBF maps obtained from arterial spin-labeling MR imaging in grading gliomas. This study was performed to investigate the effectiveness of CBF maps derived from 3D pseudocontinuous arterial spin-labeling in preoperatively assessing the grade, cellular proliferation, and prognosis of gliomas.
• ADC maps could improve the differentiation between HGG and LGG. • The mean ADC value had a closer correlation with the Ki-67 index. • The mean ADC value was an independent prognosis factor for gliomas.
To develop a quantitative assessment of collateral perfusion at CT and to investigate its value in the prediction of outcome in patients with acute ischemic stroke (AIS).
Materials and Methods:This retrospective study reviewed data from consecutive patients with AIS and an occluded M1 segment of the middle cerebral artery who underwent pretreatment perfusion CT between May 2009 and August 2017. The maximum cerebral blood flow (CBF) of collateral vessels (cCBF max ) within the Sylvian fissure was calculated for each patient. Good outcome was defined as a 90-day modified Rankin scale score of 0-2. Multivariable logistic regression analysis was used to determine the relationship between cCBF max and (a) hemorrhagic transformation and (b) clinical outcome.
Results:The final analysis included 204 patients (median age, 73 years; interquartile range, 62-80 years; 82 [40.2%] women). Multivariable logistic regression analysis showed that higher cCBF max was an independent predictor for (a) a lower risk of hemorrhagic transformation (odds ratio [OR], 0.99; 95% confidence interval [CI]: 0.98, 1.00; P = .009) after adjusting for baseline National Institutes of Health Stroke Scale (NIHSS), endovascular thrombectomy, baseline infarct core volume, and recanalization and (b) better outcome (OR, 1.02; 95% CI: 1.01, 1.03; P = .001) after adjusting for age, baseline NIHSS score, endovascular thrombectomy, hypertension, baseline infarct core volume, and recanalization, respectively.
Conclusion:The measurement of maximum cerebral blood flow of collateral vessels within the Sylvian fissure is a feasible quantitative collateral assessment at perfusion CT. Maximum cerebral blood flow of collateral vessels was associated with clinical outcome in patients with acute ischemic stroke.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.