BackgroundDeficits of kinesthesia (limb position and movement sensation) commonly limit sensorimotor function and its recovery after neuromotor injury. Sensory substitution technologies providing synthetic kinesthetic feedback might re-establish or enhance closed-loop control of goal-directed behaviors in people with impaired kinesthesia.MethodsAs a first step toward this goal, we evaluated the ability of unimpaired people to use vibrotactile sensory substitution to enhance stabilization and reaching tasks. Through two experiments, we compared the objective and subjective utility of two forms of supplemental feedback – limb state information or hand position error – to eliminate hand position drift, which develops naturally during stabilization tasks after removing visual feedback.ResultsExperiment 1 optimized the encoding of limb state feedback; the best form included hand position and velocity information, but was weighted much more heavily toward position feedback. Upon comparing optimal limb state feedback vs. hand position error feedback in Experiment 2, we found both encoding schemes capable of enhancing stabilization and reach performance in the absence of vision. However, error encoding yielded superior outcomes - objective and subjective - due to the additional task-relevant information it contains.ConclusionsThe results of this study have established the immediate utility and relative merits of two forms of vibrotactile kinesthetic feedback in enhancing stabilization and reaching actions performed with the arm and hand in neurotypical people. These findings can guide future development of vibrotactile sensory substitution technologies for improving sensorimotor function after neuromotor injury in survivors who retain motor capacity, but lack proprioceptive integrity in their more affected arm.Electronic supplementary materialThe online version of this article (doi:10.1186/s12984-017-0248-8) contains supplementary material, which is available to authorized users.
Despite distal arm impairment after brain injury is an extremely disabling consequence of neurological damage, most studies on robotic therapy are mainly focused on recovery of proximal upper limb motor functions, routing the major efforts in rehabilitation to shoulder and elbow joints. In the present study we developed a novel therapeutic protocol aimed at restoring wrist functionality in chronic stroke patients. A haptic three DoFs (degrees of freedom) robot has been used to quantify motor impairment and assist wrist and forearm articular movements: flexion/extension (FE), abduction/adduction (AA), pronation/supination (PS). This preliminary study involved nine stroke patients, from a mild to severe level of impairment. Therapy consisted in ten 1-hour sessions over a period of five weeks. The novelty of the approach was the adaptive control scheme which trained wrist movements with slow oscillatory patterns of small amplitude and progressively increasing bias, in order to maximize the recovery of the active range of motion. The primary outcome was a change in the active RoM (range of motion) for each DoF and a change of motor function, as measured by the Fugl-Meyer assessment of arm physical performance after stroke (FMA). The secondary outcome was the score on the Wolf Motor Function Test (WOLF). The FMA score reported a significant improvement (average of 9.33±1.89 points), revealing a reduction of the upper extremity motor impairment over the sessions; moreover, a detailed component analysis of the score hinted at some degree of motor recovery transfer from the distal, trained parts of the arm to the proximal untrained parts. WOLF showed an improvement of 8.31±2.77 points, highlighting an increase in functional capability for the whole arm. The active RoM displayed a remarkable improvement. Moreover, a three-months follow up assessment reported long lasting benefits in both distal and proximal arm functionalities. The experimental results of th- s preliminary clinical study provide enough empirical evidence for introducing the novel progressive, adaptive, gentle robotic assistance of wrist movements in the clinical practice, consolidating the evaluation of its efficacy by means of a controlled clinical trial.
BackgroundAlthough robot therapy is progressively becoming an accepted method of treatment for stroke survivors, few studies have investigated how to adapt the robot/subject interaction forces in an automatic way. The paper is a feasibility study of a novel self-adaptive robot controller to be applied with continuous tracking movements.MethodsThe haptic robot Braccio di Ferro is used, in relation with a tracking task. The proposed control architecture is based on three main modules: 1) a force field generator that combines a non linear attractive field and a viscous field; 2) a performance evaluation module; 3) an adaptive controller. The first module operates in a continuous time fashion; the other two modules operate in an intermittent way and are triggered at the end of the current block of trials. The controller progressively decreases the gain of the force field, within a session, but operates in a non monotonic way between sessions: it remembers the minimum gain achieved in a session and propagates it to the next one, which starts with a block whose gain is greater than the previous one. The initial assistance gains are chosen according to a minimal assistance strategy. The scheme can also be applied with closed eyes in order to enhance the role of proprioception in learning and control.ResultsThe preliminary results with a small group of patients (10 chronic hemiplegic subjects) show that the scheme is robust and promotes a statistically significant improvement in performance indicators as well as a recalibration of the visual and proprioceptive channels. The results confirm that the minimally assistive, self-adaptive strategy is well tolerated by severely impaired subjects and is beneficial also for less severe patients.ConclusionsThe experiments provide detailed information about the stability and robustness of the adaptive controller of robot assistance that could be quite relevant for the design of future large scale controlled clinical trials. Moreover, the study suggests that including continuous movement in the repertoire of training is acceptable also by rather severely impaired subjects and confirms the stabilizing effect of alternating vision/no vision trials already found in previous studies.
In stroke survivors, motor impairment is frequently associated with degraded proprioceptive and/or somatosensory functions. Here we address the question of how to use robots to improve proprioception in these patients. We used an 'assist-as-needed' protocol, in which robot assistance was kept to a minimum and was continuously adjusted during exercise. To specifically train proprioceptive functions, we alternated blocks of trials with and without vision. A total of nine chronic stroke survivors participated in the study, which consisted of a total of ten 1-h exercise sessions. We used a linear mixed-effects statistical model to account for the effects of exercise, vision and the degree of assistance on the overall performance, and to capture both the systematic effects and the individual variations. Although there was not always a complete recovery of autonomous movements, all subjects exhibited an increased amount of voluntary control. Moreover, training with closed eyes appeared to be beneficial for patients with abnormal proprioception. Our results indicate that training by alternating vision and no-vision blocks may improve the ability to use proprioception as well as the ability to integrate it with vision. We suggest that the approach may be useful in the more general case of motor skill acquisition, in which enhancing proprioception may improve the ability to physically interact with the external world.
BackgroundIn the last two decades robot training in neuromotor rehabilitation was mainly focused on shoulder-elbow movements. Few devices were designed and clinically tested for training coordinated movements of the wrist, which are crucial for achieving even the basic level of motor competence that is necessary for carrying out ADLs (activities of daily life). Moreover, most systems of robot therapy use point-to-point reaching movements which tend to emphasize the pathological tendency of stroke patients to break down goal-directed movements into a number of jerky sub-movements. For this reason we designed a wrist robot with a range of motion comparable to that of normal subjects and implemented a self-adapting training protocol for tracking smoothly moving targets in order to facilitate the emergence of smoothness in the motor control patterns and maximize the recovery of the normal RoM (range of motion) of the different DoFs (degrees of Freedom).MethodsThe IIT-wrist robot is a 3 DoFs light exoskeleton device, with direct-drive of each DoF and a human-like range of motion for Flexion/Extension (FE), Abduction/Adduction (AA) and Pronation/Supination (PS). Subjects were asked to track a variable-frequency oscillating target using only one wrist DoF at time, in such a way to carry out a progressive splinting therapy. The RoM of each DoF was angularly scanned in a staircase-like fashion, from the "easier" to the "more difficult" angular position. An Adaptive Controller evaluated online performance parameters and modulated both the assistance and the difficulty of the task in order to facilitate smoother and more precise motor command patterns.ResultsThree stroke subjects volunteered to participate in a preliminary test session aimed at verify the acceptability of the device and the feasibility of the designed protocol. All of them were able to perform the required task. The wrist active RoM of motion was evaluated for each patient at the beginning and at the end of the test therapy session and the results suggest a positive trend.ConclusionThe positive outcomes of the preliminary tests motivate the planning of a clinical trial and provide experimental evidence for defining appropriate inclusion/exclusion criteria.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.