Gd-BOPTA demonstrates the highest longitudinal r1 at all field strengths, which is ascribable to weak protein interaction. The R2/R1 ratio increases at higher field strength only for Gd-BOPTA, hence very short echo times are required for Gd-BOPTA to benefit from the higher longitudinal relaxivity.
Combined positron emission tomography (PET) and magnetic resonance imaging (MRI) is a new tool to study functional processes in the brain. Here we study brain function in response to a barrel-field stimulus simultaneously using PET, which traces changes in glucose metabolism on a slow time scale, and functional MRI (fMRI), which assesses fast vascular and oxygenation changes during activation. We found spatial and quantitative discrepancies between the PET and the fMRI activation data. The functional connectivity of the rat brain was assessed by both modalities: the fMRI approach determined a total of nine known neural networks, whereas the PET method identified seven glucose metabolism-related networks. These results demonstrate the feasibility of combined PET-MRI for the simultaneous study of the brain at activation and rest, revealing comprehensive and complementary information to further decode brain function and brain networks.
Hybrid PET/MR combines the exceptional molecular sensitivity of PET with the high resolution and versatility of MR imaging. Simultaneous data acquisition additionally promises the use of MR to enhance the quality of PET images, for example, by respiratory motion correction. This advantage is especially relevant in thoracic and abdominal areas to improve the visibility of small lesions with low radiotracer uptake and to enhance uptake quantification. In this work, the applicability and performance of an MR-based method of respiratory motion correction for PET tumor imaging was evaluated in phantom and patient studies. Methods: PET list-mode data from a motion phantom with 22 Na point sources and 5 patients with tumor manifestations in the thorax and upper abdomen were acquired on a simultaneous hybrid PET/MR system. During the first 3 min of a 5-min PET scan, the respiration-induced tissue deformation in the PET field of view was recorded using a sagittal 2-dimensional multislice gradient echo MR sequence. MR navigator data to measure the location of the diaphragm were acquired throughout the PET scan. Respiration-gated PET data were coregistered using the MR-derived motion fields to obtain a single motion-corrected PET dataset. The effect of motion correction on tumor visibility, delineation, and radiotracer uptake quantification was analyzed with respect to uncorrected and gated images. Results: Image quality in terms of lesion delineation and uptake quantification was significantly improved compared with uncorrected images for both phantom and patient data. In patients, in head-feet line profiles of 14 manifestations, the slope became steeper by 66.7% (P 5 0.001) and full width at half maximum was reduced by 20.6% (P 5 0.001). The mean increase in maximum standardized uptake value, lesion-to-background ratio (contrast), and signal-to-noise ratio was 28.1% (P 5 0.001), 24.7% (P 5 0.001), and 27.3% (P 5 0.003), respectively. Lesion volume was reduced by an average of 26.5% (P 5 0.002). As opposed to the gated images, no increase in background noise was observed.However, motion correction performed worse than gating in terms of contrast (211.3%, P 5 0.002), maximum standardized uptake value (210.7%, P 5 0.003), and slope steepness (219.3%, P 5 0.001). Conclusion: The proposed method for MR-based respiratory motion correction of PET data proved feasible and effective. The short examination time and convenience (no additional equipment required) of the method allow for easy integration into clinical routine imaging. Performance compared with gating procedures can be further improved using list-mode-based motion correction. Hybri d PET/MR imaging systems combine the high molecular sensitivity of PET and the superior resolution and versatility of MR imaging for improved tumor imaging (1). Furthermore, systems capable of simultaneous PET/MR data acquisition can improve PET image quality and radiotracer uptake quantification by the use of MR-based correction methods, for example, for respiratory motion.Respiratory moti...
aThe influence of passive shortening and stretching of the calf muscles on diffusion characteristics was investigated. The diffusion tensor was measured in transverse slices through the lower leg of eight healthy volunteers (29 W 7 years) on a 3 T whole-body MR unit in three different positions of the foot (40-plantarflexion, neutral ankle position (0-), and S10-dorsiflexion in the ankle). Maps of the mean diffusivity, the three eigenvalues of the tensor and fractional anisotropy (FA) were calculated. Results revealed a distinct dependence of the mean diffusivity and FA on the foot position and the related shortening and stretching of the muscle groups. The tibialis anterior muscle showed a significant increase of 19% in FA with increasing dorsiflexion, while the FA of the antagonists significantly decreased ($20%). Regarding the mean diffusivity of the diffusion tensor, the muscle groups showed an opposed response to muscle elongation and shortening. Regarding the eigenvalues of the diffusion tensor, l 2 and l 3 showed significant changes in relation to muscle length. In contrast, no change in l 1 could be found. This work reveals significant changes in diffusional characteristics induced by passive muscle shortening and stretching.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.